欢迎访问ic37.com |
会员登录 免费注册
发布采购

PQ60018QTA40NKS 参数 Datasheet PDF下载

PQ60018QTA40NKS图片预览
型号: PQ60018QTA40NKS
PDF下载: 下载PDF文件 查看货源
内容描述: 四分之一砖DC / DC转换器 [Quarter-brick DC/DC Converter]
分类和应用: 转换器
文件页数/大小: 13 页 / 484 K
品牌: SYNQOR [ SYNQOR WORLDWIDE HEADQUARTERS ]
 浏览型号PQ60018QTA40NKS的Datasheet PDF文件第5页浏览型号PQ60018QTA40NKS的Datasheet PDF文件第6页浏览型号PQ60018QTA40NKS的Datasheet PDF文件第7页浏览型号PQ60018QTA40NKS的Datasheet PDF文件第8页浏览型号PQ60018QTA40NKS的Datasheet PDF文件第9页浏览型号PQ60018QTA40NKS的Datasheet PDF文件第10页浏览型号PQ60018QTA40NKS的Datasheet PDF文件第11页浏览型号PQ60018QTA40NKS的Datasheet PDF文件第13页  
Input:  
Output:  
35-75 V  
1.8 V  
Current:  
Package:  
40 A  
Quarter-brick  
Technical Specification  
Startup Inhibit Period: The Startup Inhibit Period ensures that  
the converter will remain off for approximately 200ms when it is  
shut down for any reason. When an output short is present, this  
generates a 5Hz "hiccup mode," which prevents the converter  
from overheating. In all, there are seven ways that the converter  
can be shut down, initiating a Startup Inhibit Period:  
When the input voltage rises above the UVL threshold, the Input  
Under-Voltage Lockout is released, and a Startup Inhibit Period is  
initiated. At the end of this delay, the ON/OFF pin is evaluated,  
and since it is active, the unit turns on.  
At time t1, the unit is disabled by the ON/OFF pin, and it cannot  
be enabled again until the Startup Inhibit Period has elapsed.  
• Input Under-Voltage Lockout  
• Input Over-Voltage Shutdown (not present in Quarter-brick)  
• Output Over-Voltage Protection  
• Over Temperature Shutdown  
• Current Limit  
When the ON/OFF pin goes high after t2, the Startup Inhibit  
Period has elapsed, and the output turns on within the typical  
Turn-On Time.  
RoHS Compliance: The EU led RoHS (Restriction of Hazardous  
Substances) Directive bans the use of Lead, Cadmium,  
Hexavalent Chromium, Mercury, Polybrominated Biphenyls  
(PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical  
and Electronic Equipment. SynQor products are currently 5/6  
RoHS compliant with lead being the exception. For more infor-  
mation please visit our RoHS Compliance / Lead Free Initiative  
web page or e-mail us at rohs@synqor.com.  
• Short Circuit Protection  
• Turned off by the ON/OFF input  
Figure F shows three turn-on scenarios, where a Startup Inhibit  
Period is initiated at t0, t1, and t2:  
Before time t0, when the input voltage is below the UVL threshold,  
the unit is disabled by the Input Under-Voltage Lockout feature.  
V
in  
Under-Voltage  
Lockout Turn-On  
Threshold  
ON/OFF  
(pos logic)  
ON  
OFF  
ON  
OFF  
ON  
4ms (typical  
turn on time)  
V
out  
200ms  
(typical start-up  
inhibit period)  
200ms  
200ms  
t
t0  
t1  
t2  
Figure F: Startup Inhibit Period (turn-on time not to scale)  
Product # PQ60018QTA40  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-2QT618C Rev. C  
09/08/05  
Page 12