欢迎访问ic37.com |
会员登录 免费注册
发布采购

PQ48150QGA07NKS 参数 Datasheet PDF下载

PQ48150QGA07NKS图片预览
型号: PQ48150QGA07NKS
PDF下载: 下载PDF文件 查看货源
内容描述: 100瓦,无需散热器,隔离式DC / DC转换器 [100 Watt, No Heatsink, Isolated DC/DC Converter]
分类和应用: 转换器电源电路
文件页数/大小: 13 页 / 730 K
品牌: SYNQOR [ SYNQOR WORLDWIDE HEADQUARTERS ]
 浏览型号PQ48150QGA07NKS的Datasheet PDF文件第5页浏览型号PQ48150QGA07NKS的Datasheet PDF文件第6页浏览型号PQ48150QGA07NKS的Datasheet PDF文件第7页浏览型号PQ48150QGA07NKS的Datasheet PDF文件第8页浏览型号PQ48150QGA07NKS的Datasheet PDF文件第9页浏览型号PQ48150QGA07NKS的Datasheet PDF文件第10页浏览型号PQ48150QGA07NKS的Datasheet PDF文件第11页浏览型号PQ48150QGA07NKS的Datasheet PDF文件第13页  
Technical Specification  
Quarter  
48V 15V  
6.7A  
out  
in  
Brick  
Startup Inhibit Period: The Startup Inhibit Period ensures  
that the converter will remain off for at least 200ms when it is  
shut down for any reason. When an output short is present,  
this generates a 5Hz "hiccup mode," which prevents the con-  
verter from overheating. In all, there are seven ways that the  
converter can be shut down, initiating a Startup Inhibit Period:  
Before time t0, when the input voltage is below the UVL thresh-  
old, the unit is disabled by the Input Under-Voltage Lockout fea-  
ture. When the input voltage rises above the UVL threshold, the  
Input Under-Voltage Lockout is released, and a Startup Inhibit  
Period is initiated. At the end of this delay, the ON/OFF pin is  
evaluated, and since it is active, the unit turns on.  
• Input Under-Voltage Lockout  
• Input Over-Voltage Shutdown (not present in Quarter-brick)  
• Output Over-Voltage Protection  
• Over Temperature Shutdown  
• Current Limit  
At time t1, the unit is disabled by the ON/OFF pin, and it can-  
not be enabled again until the Startup Inhibit Period has  
elapsed.  
When the ON/OFF pin goes high after t2, the Startup Inhibit  
Period has elapsed, and the output turns on within the typical  
Turn-On Time.  
• Short Circuit Protection  
• Turned off by the ON/OFF input  
Figure F shows three turn-on scenarios, where a Startup Inhibit  
Period is initiated at t0, t1, and t2:  
V
in  
Under-Voltage  
Lockout Turn-On  
Threshold  
ON/OFF  
(pos logic)  
ON  
OFF  
ON  
OFF  
ON  
4ms (typical  
turn on time)  
V
out  
200ms  
(typical start-up  
inhibit period)  
200ms  
200ms  
t
t0  
t1  
t2  
Figure F: Startup Inhibit Period (turn-on time not to scale)  
Product # PQ48150QGA07  
Phone 1-888-567-9596  
Doc.# 005-2QG415D Rev. D  
8/16/02  
Page 12