MQME-270-P
Current: 2A
Technical Specification
CONSTRUCTION AND ENVIRONMENTAL STRESS SCREENING OPTIONS
ES-Grade
(-55 ºC to +125 ºC)
(Element Evaluation)
HB-Grade
(-55 ºC to +125 ºC)
(Element Evaluation)
Consistent with
MIL-STD-883F
C-Grade
(-40 ºC to +100 ºC)
Screening
Internal Visual
Yes
No
Yes
Yes
*
Condition B
(-55 ºC to +125 ºC)
Condition C
(-65 ºC to +150 ºC)
Temperature Cycle
Method 1010
Constant
Acceleration
Method 2001
(Y1 Direction)
Condition A
(5000g)
No
500g
Method 1015
Load Cycled
Burn-in
• 10s period
24 Hrs @ +125 ºC
96 Hrs @ +125 ºC
160 Hrs @ +125 ºC
• 2s @ 100% Load
• 8s @ 0% Load
Method 5005
(Group A)
Final Electrical Test
+25 ºC
-45, +25, +100 ºC
Full QorSeal
-55, +25, +125 ºC
Full QorSeal
Mechanical Seal,
Thermal, and Coating
Process
Full QorSeal
External Visual
2009
Yes
Yes
*
Construction Process
QorSeal
QorSeal
QorSeal
* Per IPC-A-610 (Rev. D) Class 3
MilQorꢀconvertersꢀandꢀfiltersꢀareꢀofferedꢀinꢀfourꢀvariationsꢀofꢀconstructionꢀtechniqueꢀandꢀenvironmentalꢀstressꢀscreeningꢀoptions.ꢀꢀTheꢀ
threeꢀhighestꢀgrades,ꢀC,ꢀES,ꢀandꢀHB,ꢀallꢀuseꢀSynQor’sꢀproprietaryꢀQorSeal™ꢀHi-RelꢀassemblyꢀprocessꢀthatꢀincludesꢀaꢀParylene-Cꢀ
coating of the circuit, a high performance thermal compound filler, and a nickel barrier gold plated aluminum case. Each succes-
sivelyꢀhigherꢀgradeꢀhasꢀmoreꢀstringentꢀmechanicalꢀandꢀelectricalꢀtesting,ꢀasꢀwellꢀasꢀaꢀlongerꢀburn-inꢀcycle.ꢀꢀTheꢀES-ꢀandꢀHB-Gradesꢀ
areꢀalsoꢀconstructedꢀofꢀcomponentsꢀthatꢀhaveꢀbeenꢀprocuredꢀthroughꢀanꢀelementꢀevaluationꢀprocessꢀthatꢀpre-qualifiesꢀeachꢀnewꢀ
batch of devices.
Product # MQME-270-P
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2ME027P Rev. 2
03/16/09
Page 10