Technical
Specification
IQ36-HP Family
IQ36-HP Standards Compliance & Qualification Testing
STANDARDSꢀCOMPLIANCE
Parameter
ꢀNotesꢀ&ꢀConditions
ꢀSTANDARDSꢀCOMPLIANCE
ꢀUL/cULꢀ60950-1ꢀꢀ
ꢀEN60950-1ꢀꢀ
ꢀFileꢀ#ꢀE194341,ꢀBasicꢀinsulation
ꢀCertifiedꢀbyꢀTUV
ꢀNeedleꢀFlameꢀTestꢀ(IECꢀ695-2-2)
ꢀIECꢀ61000-4-2
ꢀTestꢀonꢀentireꢀassembly;ꢀboardꢀ&ꢀplasticꢀcomponentsꢀUL94V-0ꢀcompliant
ꢀESDꢀtest,ꢀ8ꢀkVꢀ-ꢀNP,ꢀ15ꢀkVꢀairꢀ-ꢀNPꢀ(NormalꢀPerformance)
Note:ꢀAnꢀexternalꢀinputꢀfuseꢀmustꢀalwaysꢀbeꢀusedꢀtoꢀmeetꢀtheseꢀsafetyꢀrequirements.ꢀꢀContactꢀSynQorꢀforꢀofficialꢀsafetyꢀcertificatesꢀonꢀnew
releasesꢀorꢀdownloadꢀfromꢀtheꢀSynQorꢀwebsite.
QUALIFICATIONꢀTESTING
Parameter
#ꢀUnits ꢀTestꢀConditions
ꢀQUALIFICATIONꢀTESTING
ꢀLifeꢀTest
32
ꢀ95%ꢀratedꢀVinꢀandꢀload,ꢀunitsꢀatꢀderatingꢀpoint,ꢀ1000ꢀhours
ꢀVibration
5
5
10
5
5
5
ꢀ10-55ꢀHzꢀsweep,ꢀ0.060"ꢀtotalꢀexcursion,ꢀ1ꢀmin./sweep,ꢀ120ꢀsweepsꢀforꢀ3ꢀaxis
ꢀ100gꢀminimum,ꢀ2ꢀdropsꢀinꢀxꢀandꢀyꢀaxis,ꢀ1ꢀdropꢀinꢀzꢀaxis
ꢀ-40ꢀ°Cꢀtoꢀ100ꢀ°C,ꢀunitꢀtemp.ꢀrampꢀ15ꢀ°C/min.,ꢀ500ꢀcycles
ꢀToperatingꢀ=ꢀminꢀtoꢀmax,ꢀVinꢀ=ꢀminꢀtoꢀmax,ꢀfullꢀload,ꢀ100ꢀcycles
ꢀTmin-10ꢀ°CꢀtoꢀTmax+10ꢀ°C,ꢀ5ꢀ°Cꢀsteps,ꢀVinꢀ=ꢀminꢀtoꢀmax,ꢀ0-105%ꢀload
ꢀ85ꢀ°C,ꢀ85%ꢀRH,ꢀ1000ꢀhours,ꢀcontinuousꢀVinꢀappliedꢀexceptꢀ5ꢀmin/day
ꢀMIL-STD-883,ꢀmethodꢀ2003
ꢀMechanicalꢀShock
ꢀTemperatureꢀCycling
ꢀPower/ThermalꢀCycling
ꢀDesignꢀMarginality
Humidity
ꢀSolderability
15ꢀpins