Input:
Outputs:
Power:
35-75V
+12V & -12V
60W
Package:
Quarter-brick
Technical Specification
100
95
90
85
80
75
70
65
60
6
5
4
3
2
1
0
35 Vin
48 Vin
75 Vin
35 Vin
48 Vin
75 Vin
0
12
24
36
48
60
0
12
24
36
48
60
Total Output Power (W)
Total Output Power (W)
Figure 1: Efficiency vs. output power, from 0 load to full load with 50%
Figure 2: Power dissipation vs. output power, from 0 load to full load
load on -12V output and 50% load on +12V output at minimum, nomi-
with 50% load on -12V output and 50% load on +12V output at mini-
nal, and maximum input voltage at 25
°C.
mum, nominal, and maximum input voltage at 25°C.
100
95
90
85
80
75
70
65
60
6
5
4
3
2
1
0
35 Vin
48 Vin
75 Vin
35 Vin
48 Vin
75 Vin
34.5/1.2
27.5/8.5
19.2/16.9
10.9/25.2
2.4/33.5
34.5/1.2
27.5/8.5
19.2/16.9
10.9/25.2
2.4/33.5
Output Power (W), -12Vout/+12Vout
Output Power (W), -12Vout/+12Vout
Figure 3: Efficiency vs. output power, with total output power fixed at
Figure 4: Power dissipation vs. output power, with total output power
60% load (36W) and loads split as shown between -12V and +12V out-
fixed at 60% load (36W) and loads split as shown between -12V and
puts at minimum, nominal, and maximum input voltage at 25
°C.
+12V outputs at minimum, nominal, and max input voltage at 25°C.
93
92
91
90
89
88
87
7.0
6.0
5.0
4.0
25 C
40 C
55 C
3.0
2.0
25 C
40 C
55 C
0
100
200
300
400
500
0
100
200
300
400
500
Air Flow (LFM)
Air Flow (LFM)
Figure 5: Efficiency vs. load current, with 80% load and 50/50 voltage
split (2A load on -12V and 2A load on +12V) over variations in temper-
ature and airflow.
Figure 6: Power dissipation vs. load current, with 80% load and 50/50
voltage split (2A load on -12V and 2A load on +12V) over variations in
temperature and airflow.
Product # DQ61212QMA06
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2DQ612E Rev. C
01/11/06