Input Filtering and External Capacitance: Figure E pro-
vides a diagram showing the internal input filter components.
This filter dramatically reduces input terminal ripple current,
which otherwise could exceed the rating of an external elec-
trolytic input capacitor. The recommended external input capac-
itance is specified in the “Input Characteristics” section. More
detailed information is available in the application note titled
“EMI Characteristics” on the SynQor website.
L
Vin(+)
C
_
Vin( )
Figure E: Internal Input Filter Diagram (values listed on page 3).
Startup Inhibit Period: The Startup Inhibit Period ensures that
the converter will remain off for at least 200ms when it is shut
down for any reason. When an output short is present, this gen-
erates a 5Hz "hiccup mode," which prevents the converter from
overheating. In all, there are seven ways that the converter can
be shut down, initiating a Startup Inhibit Period:
Before time t0, when the input voltage is below the UVL threshold,
the unit is disabled by the Input Under-Voltage Lockout feature.
When the input voltage rises above the UVL threshold, the Input
Under-Voltage Lockout is released, and a Startup Inhibit Period is
initiated. At the end of this delay, the ON/OFF pin is evaluated,
and since it is active, the unit turns on.
• Input Under-Voltage Lockout
• Input Over-Voltage Shutdown (not present in Quarter-brick)
• Output Over-Voltage Protection
• Over Temperature Shutdown
• Current Limit
At time t1, the unit is disabled by the ON/OFF pin, and it cannot
be enabled again until the Startup Inhibit Period has elapsed.
When the ON/OFF pin goes high after t2, the Startup Inhibit
Period has elapsed, and the output turns on within the typical
Turn-On Time.
• Short Circuit Protection
• Turned off by the ON/OFF input
Figure F shows three turn-on scenarios, where a Startup Inhibit
Period is initiated at t0, t1, and t2:
V
in
Under-Voltage
Lockout Turn-On
Threshold
ON/OFF
(pos logic)
ON
OFF
ON
OFF
ON
4ms (typical
turn on time)
V
out
200ms
(typical start-up
inhibit period)
200ms
200ms
t
t0
t1
t2
Figure F: Startup Inhibit Period (turn-on time not to scale)