 浏览型号AQ0400IU48SAIND的Datasheet PDF文件第1页浏览型号AQ0400IU48SAIND的Datasheet PDF文件第3页浏览型号AQ0400IU48SAIND的Datasheet PDF文件第4页浏览型号AQ0400IU48SAIND的Datasheet PDF文件第5页浏览型号AQ0400IU48SAIND的Datasheet PDF文件第6页浏览型号AQ0400IU48SAIND的Datasheet PDF文件第7页浏览型号AQ0400IU48SAIND的Datasheet PDF文件第8页浏览型号AQ0400IU48SAIND的Datasheet PDF文件第9页  
85-264 V  
12/24/36/48V Semi-reg  
400 W Series  
Industrial  
AC Input:  
DC Output:  
Power:  
RMS  
.
Grade:  
Technical Specification  
ACuQor 400W Series ELECTRICAL CHARACTERISTICS  
All specifications typical with T = 25 °C, unless otherwise specified.  
A
MAIN OUTPUT SPECIFICATIONS  
GENERAL SPECIFICATIONS  
Output power (continuous) 85-132/170-264 Vrms  
400 W  
500 W  
See Figure 10  
Fundamental ripple freq.  
Input  
Output  
500 kHz  
250 kHz  
(5 s transient)  
85-132/170-264 Vrms  
132-170 Vrms  
Audible noise  
Fan speed varies with temp.  
39 dBA @ 1 m max.  
Nominal DC output  
voltage (at 250W)  
(Semi-regulated)  
12 Vout  
24 Vout  
36 Vout  
48 Vout  
12.4 V  
25 V  
37.5 V  
50 V  
Weight (EA \ EC)  
(SC \ RC)  
343 g (12.1 oz) \ 446 g (15.7 oz)  
846 g (29.8 oz) \ 879 g (31 oz)  
1224 g (43.2 oz) \ 1298 g (45.8 oz)  
(UC \ TC)  
MTBF  
MIL-217  
Demonstrated  
343.6 kHours  
TBD kHours  
Efficiency (see figs. 3 - 10) 12 Vout, 115 Vrms, 400 W  
48 Vout, 115 Vrms, 400 W  
88% typ.  
90% typ.  
89% typ.  
91% typ.  
ISOLATION SPECIFICATIONS  
12 Vout, 230 Vrms, 400 W  
48 Vout, 230 Vrms, 400 W  
Isolation voltage  
Input to output  
Input to ground  
Output to ground  
3000 Vrms  
1500 Vrms  
500 Vrms  
Hold-up time (to -20%)  
12 Vout  
24 / 36 / 48 Vout  
16 ms @ 400 W  
20 ms @ 400 W  
Maximum load capacitance 12 Vout  
16,000 µF  
8,000 µF  
4,000 µF  
2,000 µF  
Insulation resistance  
Leakage currents  
Output to ground  
10 MΩ min.  
See Note 2  
24 Vout  
36 Vout  
48 Vout  
ENVIRONMENTAL CHARACTERISTICS  
Output ripple voltage  
Switching frequency (20 MHz BW)  
Twice line frequency (at 300W)  
0.5% p-p  
5.0% p-p  
Thermal performance  
Operating ambient (see Figure 9)  
Non-operating ambient  
Non-condensing  
0 ºC to +70 ºC  
-40 ºC to +85 ºC  
Relative humidity  
Altitude  
5-95% RH  
Turn-on delay  
2 s max.  
Operating  
Non-operating  
10,000 ft max.  
30,000 ft max.  
Transient response  
Iout steps from 50-75%  
At 0.2 A/µs  
3% typ / 6% max.  
dev.  
100 ms recovery  
Random vibration  
Shock  
5-500 Hz  
0.03 g2/Hz  
20 g peak  
Half-sine, 10 ms, 3 axes  
Overvoltage protection  
Short circuit protection  
Total regulation  
Cyclic restart  
110-120%  
115% rated Iout  
±6.0%  
EMC CHARACTERISTICS  
Conducted emissions  
Cyclic operation  
EN55011 and EN55022, FCC  
part15  
Level B  
Over line, load and temperature  
Always on (See Note 1)  
Automatic recovery  
Auxillary Output  
5 V @ 50 mA  
Line frequency harmonics EN61000-3-2  
Class A  
Clause 5b  
Level 3  
Level 3  
Level 3  
Level 3  
Level 3  
Level 3  
3 A/m  
Thermal protection  
REMOTE_ENABLE  
+125 ºC (PCB Temp)  
Voltage fluctuations  
ESD air  
EN61000-3-3  
EN61000-4-2  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
EN61000-4-5  
EN61000-4-6  
EN61000-4-8  
EN61000-4-11  
Input Low Voltage  
Input High Voltage  
0.45 V (max)  
4.15 V (min)  
ESD contact  
INPUT SPECIFICATIONS  
AC input voltage  
Radiated immunity  
Fast transients  
Universal range  
85-264 Vrms  
47-63 Hz  
Input frequency  
Line surge immunity  
Conducted immunity  
Power freq. mag. field  
Voltage dip immunity  
Input current  
115 Vrms @ 400 W  
230 Vrms @ 400 W  
4 Arms  
2 Arms  
Power factor  
>0.98  
Perf Criteria A, A, B  
<5% UT 10 ms,  
70% UT 500 ms,  
40% UT 100 ms  
Input surge current  
Internal input fuses  
264 Vrms (cold start)  
Both AC lines  
40 A max.  
6.3 A  
SAFETY AGENCY CERTIFICATIONS (pending)  
All certification marks appear on individual unit labels.  
UL60950  
IEC/EN 60950  
CE Marked  
cUL CSA Standards  
NOTES:  
1. Derate 1 mA per °C above 50 °C ambient temperature.  
2. Leakage currents:  
AC Leakage Current  
AC Line Connection  
from Input to Earth  
Normal Open Neutral  
Condition  
Fault  
240 V L-N, 1 phase  
ACuQor Typical at  
110% nominal input 208 V L-L, 120 V L-N, 1 of 3 phases  
400 µA  
200 µA  
200 µA  
800 µA  
400 µA  
400 µA  
voltage 60 Hz  
240 V L-N-L, 120 V L-N, split phase  
Product # AQ0400IUxx Series  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-005052 Rev. A  
09/08/08  