SM59A16U1  
8-Bit Micro-controller  
64KB with ISP Flash  
& 6K+256B RAM embedded  
POLARITY0 = 1 - PWM0 Polarity active high  
13.13 Fault Configure ( FLTCONFIG )  
When FLTA or FLTB are in use, if hardware detects any abnormal signals, the status of PMW will shift to inactive  
automatically.  
13.14 PWM Fault Inputs  
The PWM module provides a fault function via FLTA and FLTB tw0 output. To disable the output signals of the PWM is  
their main function and as well as to enter an inactive status. When the fault occurs, the hardware will performer  
forthwith and shift the PWM in an inactive status; and meanwhile remain power-on connected to the PWM . Under  
normal working status, either low or high active can be directed by the users by simple operations.  
Each of the fault inputs have two modes of operation  
Inactive Mode  
If the Fault occurs, the output signals of the PWM is deactivated. The status of the PWM will remain in inactive  
and correspond to flag of the FLTxS flag and also set it up. If the PWM need to be recovered in a normal output  
working status by the time the Fault flag of the FLTxS status must be cleared by the software.  
Cycle-by-Cycle Mode  
When the Fault function occurs, the output of the PWM is deactived. The status of the PWM pin will remain in  
inactive status and correspond to flag of the FLTxS flag and set it up. When the Fault is relieved, the FLTxS will  
be relatively cleared, and the output of the PWM will be recovered to normal working status.  
Mnemonic: FLTCONFIG  
Address: DBh  
Reset  
7
6
5
4
3
2
1
0
BRFEN  
FLTBS  
FLTBMOD  
FLTBEN  
FLTCON  
FLTAS  
FLTAMOD  
FLTAEN  
80H  
BRFEN Breakpoint Fault Enable  
BRFEN = 0 - Disable  
BRFEN = 1 - Enable  
FLTBS Fault B status, must be cleared by SW(inactive mode)  
FLTBS = 0 - No Fault  
FLTBS = 1 - /FLTB is asserted.  
FLTBMOD FLTB Mode Set  
FLTBMOD = 0 - inactive mode  
FLTBMOD = 1 - cycle-by-cycle mode  
FLTBEN FLTB Active Set  
FLTBEN = 0 - Disable Fault B function  
FLTBEN = 1 - Enable Fault B function  
FLTCON 0 = inactive PWM[5:0]  
1 = inactive PWM[7:0]  
FLTAS Fault A status, must be cleared by SW(inactive mode)  
FLTAS = 0 - No Fault  
Specifications subject to change without notice contact your sales representatives for the most recent information.  
ISSFD-M071 Ver A SM59A16U1 04/12/2013  
- 94 -  