WIREWOUND CHIP INDUCTORS
SCI1008S SERIES
Climatic Test :
ITEM
SPECIFICATION
TEST CONDITIONS / TEST METHODS
-40°C ~ +125°C
1
2
Temperature
Characteristics
Temperature : 40±2°C
Humidity
Relative Humidity : 90~95%
Resistance
Time : 96hrs ±2hrs
Measured after exposure in the room condition for 2hrs
Appearance : No damage
L change : within ±10%
Q change : within ±20%
Temperature : -40±2°C
Time : 48±2hrs
3
4
Low Temperature
Storage Test
Inductors are to be tested after 1 hour at room
temperature.
One cycle :
Thermal Shock
Test
Step
Temperature (°C)
-25±3
Time (min)
1
2
3
4
30
15
30
15
25±2
85±3
25±2
Total : 5 cycles
Temperature : 125±2°C
Time : 48±2hrs
5
High Temperature
Storage Test
Load : Allowed DC current
There should be no
evidence of short of
open circuit.
Temperature : 85±2°C
Time : 1000±12hrs
6
7
High Temperature
Load Life Test
Load : Allowed DC current
Temperature : 40±2°C
Relative Humidity : 90~95%
Time : 1000±12hrs
Humidity Load
Life
Load : Allowed DC current
NOTE : Specifications subject to change without notice. Please check our website for latest information.
22.06.2010
SUPERWORLD ELECTRONICS (S) PTE LTD
PG. 8