HV6008
Electrical Characteristics (over recommended operating conditions unless noted)
DC Characteristics
Symbol
Parameter
Min
Typ
Max
Units
Conditions
VDD1
VI = 4V, VDD1 = -6V
VI = 4V, VDD2 = +6V
VDD1 = -4.5V,
IDD1,2
VDD supply current
500
µA
VDD2
VIH
VIL
Logic input high
Logic input low
Logic output high
+2
VDD1
+2
VDD2
-2
V
V
V
VDD2 = +4.5V
VOH
VDD1 = -4.5V
VDD2 = +4.5V
IOH = -15µA
IOL = 250µA
VOL
Logic output low
-2
V
IIH
High-level logic input current
Low-level logic input current
High voltage supply current
High voltage supply current
Output voltage high
+3
-50
+1
-1
µA
µA
mA
mA
V
VI = VDD, VDD1,2 = max
VI = 0V, VDD1,2 = max
Static, no load
IIL
IPP
INN
VOH
VCL
VOL
ZOH
ZCL
ZOL
IO
Static, no load
+39
-20
VPP, VNN = ±40
No load
Output voltage clamp
+20
-39
mV
V
Output voltage low
Output switch impedence high
Output switch impedance clamp
Output switch impedance low
1000
500
VPP, VNN = ±40
IO = ±15mA
Ω
700
DC output current
Output H or L
Data out H or L
5
mA
1 output only
150
µA
AC Characteristics
Symbol
Parameter
Width of high data pulse
Width of low data pulse
Min
Typ
Max
Units
Conditions
tWH
tWL
tSU
tH
500
500
25
ns
ns
ns
ns
%
Data set-up time before clock falls
Data hold time after clock falls
Phase shift duty cycle
10
50
Recommended Operating Conditions
Symbol
VDD1
VDD2
VPP
Parameter
Min
-4
Typ
Max
-6
Units
V
Logic supply voltage
Logic supply voltage
High voltage supply
High voltage supply
High-level input voltage
Low-level input voltage
+4
+6
V
+10
-10
+2V
-2V
+40
-40
VDD2
VDD1
±80
+70
1
V
VNN
VIH
V
V
VIL
V
IO Pk.
TA
Peak output current (any state)
Operating free-air temperature
Input data rate
mA
°C
MHz
KHz
-40
fDIN
fPS
Phase shift rate
20
Note:
Power-up sequence should be the following:
1. Connect ground.
3. Set all inputs (Data, CLK, Enable, etc.) to a known state.
2. Apply VDD
.
4. Apply VPP and VNN.
Power-down sequence should be the reverse of the above.