HV6008
Electrical Characteristics
(over recommended operating conditions unless noted)
DC Characteristics
Symbol
I
DD1,2
V
IH
V
IL
V
OH
V
OL
I
IH
I
IL
I
PP
I
NN
V
OH
V
CL
V
OL
Z
OH
Z
CL
Z
OL
I
O
Parameter
V
DD
supply current
Logic input high
Logic input low
Logic output high
Logic output low
High-level logic input current
Low-level logic input current
High voltage supply current
High voltage supply current
Output voltage high
Output voltage clamp
Output voltage low
Output switch impedence high
Output switch impedance clamp
Output switch impedance low
DC output current
Output H or L
Data out H or L
1000
500
700
5
150
mA
µA
Ω
V
PP
, V
NN
=
±40
I
O
=
±15mA
1 output only
+39
-20
+20
-39
V
DD1
V
DD2
+2
V
DD1
+2
-2
+3
-50
+1
-1
Min
Typ
Max
500
V
DD2
-2
Units
µA
V
V
V
V
µA
µA
mA
mA
V
mV
V
Conditions
V
I
= 4V, V
DD1
= -6V
V
I
= 4V, V
DD2
= +6V
V
DD1
= -4.5V,
V
DD2
= +4.5V
V
DD1
= -4.5V
V
DD2
= +4.5V
I
OH
= -15µA
I
OL
= 250µA
V
I
= V
DD
, V
DD1,2
= max
V
I
= 0V, V
DD1,2
= max
Static, no load
Static, no load
V
PP
, V
NN
=
±40
No load
AC Characteristics
Symbol
t
WH
t
WL
t
SU
t
H
Parameter
Width of high data pulse
Width of low data pulse
Data set-up time before clock falls
Data hold time after clock falls
Phase shift duty cycle
Min
500
500
25
10
50
Typ
Max
Units
ns
ns
ns
ns
%
Conditions
Recommended Operating Conditions
Symbol
V
DD1
V
DD2
V
PP
V
NN
V
IH
V
IL
I
O Pk.
T
A
f
DIN
f
PS
Logic supply voltage
Logic supply voltage
High voltage supply
High voltage supply
High-level input voltage
Low-level input voltage
Peak output current (any state)
Operating free-air temperature
Input data rate
Phase shift rate
-40
Parameter
Min
-4
+4
+10
-10
+2V
-2V
Typ
Max
-6
+6
+40
-40
V
DD2
V
DD1
±80
+70
1
20
Units
V
V
V
V
V
V
mA
°C
MHz
KHz
Note:
Power-up sequence should be the following:
1. Connect ground.
2. Apply V
DD
.
Power-down sequence should be the reverse of the above.
3.
4.
Set all inputs (Data, CLK, Enable, etc.) to a known state.
Apply V
PP
and V
NN
.
2