HV3527
Electrical Characteristics
(over recommended operating conditions unless noted)
DC Characteristics
Symbol
I
DD
I
DDQ
I
PP
I
IH
I
IL
V
OH
V
OL
V
OC
Parameter
V
DD
Supply Current
Quiescent V
DD
Supply Current
High Voltage Supply Current
Min
Typ
Max
25
Units
mA
µA
mA
mA
µA
µA
V
V
10
1.0
V
PP
+1.5
-1.5
V
V
V
V
Conditions
f
CLK
= 6MHz, f
DATA
= 3MHz
LE = LOW
200
0.50
0.50
High-Level Logic Input Current
Low-Level Logic Input Current
High-Level Output
HV
OUT
Data Out
Low-Level Output
HV
OUT
Data Out
HV
OUT
Clamp Voltage
200
V
DD
-1V
10
-10
All V
IN
= 0V or V
DD
V
PP
= 275V All outputs high
V
PP
= 275V All outputs low
V
IH
= V
DD
V
IL
= 0V
V
PP
= 275V, IHV
OUT
= -1mA
ID
OUT
= -100µA
IHV
OUT
= 1mA, V
DD
= 5V
ID
OUT
= 100µA
I
OL
= +5mA
I
OL
= -5mA
AC Characteristics
1,2
(For V
DD
= 5V; V
PP
= 275V, T
A
= 25°C)
Symbol
f
CLK
t
W
t
SU
t
H
t
WLE
t
DLE
t
SLE
t
ON
, t
OFF
t
DHL
t
DLH
t
r
, t
f
Clock Frequency
Clock Width High and Low
High
83
35
30
80
35
40
1.5
110
160
5
Parameter
Min
Typ
Max
6
Units
MHz
ns
ns
ns
ns
ns
ns
µs
ns
ns
ns
C
L
= 20pF
C
L
= 20pF
C
L
= 20pF
Conditions
Data Setup Time Before Clock Rises
Data Hold Time After Clock Rises
Width of Latch Enable Pulse
LE Delay Time Rising Edge of Clock
LE Setup Time Before Rising Edge of Clock
Time from Latch Enable to HV
OUT
Delay Time Clock to Data High to Low
Delay Time Clock to Data Low to High
All Logic Inputs
Notes:
1. Shift register speed can be as low as DC as long as Data Set-up and Hold Time meet the spec.
2. AC Characteristics are guaranteed only under V
DD
= 5V.
Recommended Operating Conditions
Symbol
V
DD
V
PP
V
IH
V
IL
T
A
Logic supply voltage
High voltage supply
High-level input voltage
Low-level input voltage
Operating free-air temperature
Parameter
Min
4.5
60
V
DD
-0.9
0
0
Typ
5.0
Max
5.5
275
V
DD
0.9
+70
Units
V
V
V
V
°C
Notes:
Power-up sequence should be the following:
1. Connect ground.
2. Apply V
DD
.
3. Set all inputs (Data, CLK, Enable, etc.) to a known state.
4. Apply V
PP
.
Power-down sequence should be the reverse of the above.
12-14