HV214
AC Electrical Characteristics
(V
Sym
t
SD
t
WLE
t
DO
t
WCL
t
SU
t
H
f
CLK
t
R
, t
F
T
ON
T
OFF
dv/dt
Parameter
Set-up time before LE rises
Time width of LE
Clock delay time to data out
Time width of CL
Set-up time data to clock
Hold time data from clock
Clock frequency
Clock rise and fall times
Turn-on time
Turn-off time
DD
= 5.0V, T
A
= 25
O
C,over recommended operating conditions unless otherwise noted)
Min
150
150
-
150
15
35
-
-
-
-
-
Typ
-
-
-
-
8.0
-
-
-
-
-
-
-
-
-
-
-
-
12
38
-
-
-
-
-
-
Max
-
-
150
-
-
-
5.0
50
5.0
5.0
20
20
20
-
-
-
300
17
50
200
200
200
200
200
200
Units Conditions
ns
ns
ns
ns
ns
ns
MHz
ns
µs
µs
---
---
---
---
---
---
50% duty cycle, f
DATA
= f
CLK
/2
---
V
SIG
= V
PP
-10V, R
LOAD
= 10KΩ
V
SIG
= V
PP
-10V, R
LOAD
= 10KΩ
V
PP
= +40V, V
NN
= -160V
V/ns
V
PP
= +125V, V
NN
= -100V
V
PP
= +210V, V
NN
= -40V
dB
dB
mA
pF
pF
F = 5MHz,
1KΩ//15pF load
F = 5MHz, 50Ω load
F = 5MHz, 50Ω load
300ns pulse width, 2% duty cycle
0V, f = 1MHz
0V, f = 1MHz
V
PP
= +40V, V
NN
= -210V, R
LOAD
= 50Ω
mV
V
PP
= +100V, V
NN
= -125V, R
LOAD
= 50Ω
V
PP
= +160V, V
NN
= -40V, R
LOAD
= 50Ω
Maximum V
SIG
slew rate
-
-
KO
K
CR
I
ID
C
SG(OFF)
C
SG(ON)
+V
SPK
-V
SPK
+V
SPK
-V
SPK
+V
SPK
-V
SPK
Off isolation
Switch crosstalk
Output switch isolation diode current
Off capacitance SW to GND
On capacitance SW to GND
-30
-58
-60
-
5.0
25
-
-
-
-
-
-
Output voltage spike
4