HV1816
Electrical Characteristics
(over operating conditions, VPP = +80V, VNN = -80V and VDD = 15V unless otherwise noted)
DC Characteristics
0°C
+25°C
typ
40
+70°C
Characteristics
Sym
Units
Test Conditions
min max
min
max
50
min
max
Switch (ON) Resistance
Switch (ON) Resistance
Switch (ON) Resistance
RONS
RONS
RONS
50
35
55
60
45
65
ohms
ohms
ohms
ISW = 5mA, VSIG = 0V
25
35
ISW = 200mA, VSIG = 0V
45
55
VPP = +50V, VNN = -50V
I
SW = 5mA, VSIG = 0V
Switch (ON) Resistance
RONS
∆RONS
ISOL
40
15
50
25
40
15
50
50
15
ohms
%
VPP = +50V, VNN = -50V
ISW = 200mA, VSIG = 0V
Switch (ON) Resistance
Matching
VPP = +50V, VNN = -50V
I
SW = 5mA, VSIG = 0V
Switch Off Leakage
Per Switch
0.5
150
µA
VSIG = VPP -10V thru 10KΩ
with 8 SWS in parallel
DC Offset Switch Off
DC Offset Switch On
500
500
10
100
100
4.5
500
500
10
500
500
10
mV
mV
pF
RL = 100KΩ
RL = 100KΩ
Pole to Pole
Switch Capacitance
CSW
DC Bias = 40V
f = 1MHz
Logic Input Capacitance
Pos. HV Supply Current
CIN
3.5
50
pF
µA
µA
mA
mA
mA
mA
A
IPPQ
INNQ
IPPQ
INNQ
IPPQ
INNQ
200
200
-200
1.6
200
ALL SWS OFF
Neg. HV Supply Current
-200
-50
0.8
-0.8
0.6
-0.6
1.5
-200
Pos. HV Supply Current
1 SW ON, ISW = 5mA
VSIG = 0V
Neg. HV Supply Current
-1.6
1.2
Pos. HV Supply Current
www.DataSheet4U.cNomeg. HV Supply Current
VPP = +50V, VNN = -50V,
1 SW ON, ISW = 5mA
-1.2
Switch Output
Peak Current
VSIG ≤ 0.1% Duty Cycle,
f = 10KHz
Logic Supply
IDD
4
6
mA
fCLK = 3MHz
Average Current
Logic Supply
IDDQ
10
500
µA
Quiescent Current
Data Out Source Current
Data Out Sink Current
ISOR
ISINK
0.7
0.7
0.8
0.8
0.9
0.9
0.7
0.7
mA
mA
VOUT = VDD - 0.7V
VOUT = 0.7V
AC Characteristics
0°C
max
+25°C
typ
+70°C
Characteristics
Sym
Units
Test Conditions
min
min
260
300
max
min
max
Set Up Time Before LE Rises
Time Width of LE
Clock Delay Time to Data Out
Turn On Time
tSD
tWLE
tDO
ns
ns
250
2.5
5.0
330
5.0
10
ns
tON
5.0
10
5.0
10
µs
RL =10KΩ
RL =10KΩ
Turn Off Time
tOFF
tWCL
KO
fCLK
µs
Time Width of CL
Off Isolation
150
-35
ns
-45
dB
MHz
Signal Freq. = 5MHz
Max Clock Freq
3.0
50% Duty Cycle
fDATA = fCLK/2
Set Up Time Data to Clock
Hold Time Data from Clock
Switch Crosstalk
tSU
th
0
ns
ns
dB
35
KCR
-45
Signal Freq. = 5MHz
13-18