HT0440
Electrical Characteristics
(Over recommended operating conditions, TA = 25°C unless otherwise specified)
DC Characteristics
Symbol
Parameter
Min
Typ
Max
300
500
Unit
µA
Conditions
I
IHA + IIHB
Total logic high input current
VA = 3.5V, VB = 3.5V, CLK = 0V
µA
VA = 3.5V, VB = 3.5V,
CLK = 500KHz
2.0
mA
VA = 3.5V, VB = 3.5V,
CLK = 2.0MHz
1.0
2.0
mA
mA
VA = 5.5V, VB = 5.5V, CLK = 0V
VA = 5.5V, VB = 5.5V,
CLK = 500KHz
VOUTA
,
Output Voltage
6.0
5.0
V
V
V
V
V
VA = 3.15V, VB = 3.15V,
CLK = 0V, no load
VOUTB
VA = 3.15V, VB = 3.15V,
CLK = 500KHz, no load
6.0
VA = 3.15V, VB = 3.15V,
CLK = 2.0MHz, no load
10.0
8.0
VA = 4.5V, VB = 4.5V,
CLK = 0V, no load
VA = 4.5V, VB = 4.5V,
CLK = 500KHz, no load
IILA
Logic low input A current
Logic low input B current
Quiescent current
10
10
10
µA
µA
µA
V
VA = 0.5V, VB = high
VA = high, VB = 0.5V
VA = 0.5V, VB = 0.5V
IILB
IILQ
VISO
VCISO
Input to output isolation voltage
Output to output isolation voltage
±400
±700
V
AC Characteristics
Symbol
td(ON)
Parameter
Min
Typ
Max
50
Unit
µs
Conditions
Turn on delay time
Rise time
See timing diagram and test circuit
CLK = 0V, CL = 600pF
tr
650
150
3.0
µs
td(OFF)
tf
Turn off delay time
Fall time
µs
ms
Recommended Conditions
Symbol
CLK
Parameter
External clock frequency
Clock input high voltage
Clock input low voltage
Logic input high voltage
Logic input low voltage
Operating temperature
Min
0.5
3.15
0
Typ
Max
2.0
5.5
0.5
5.5
0.5
+85
Unit
MHz
V
Conditions
VIHCLK
VILCLK
VIH
V
3.15
0
V
VIL
V
TA
-40
°C
2