SMS66  
Preliminary Information  
APPLICATIONS INFORMATION (CONTINUED)  
The HEALTHY and FAULT outputs of the SMS66 are  
active as long as the triggering limit remains in a fault  
condition. The RST output also remains active as long  
as the triggering limit remains in a fault condition;  
however, once the trigger source goes away the RST  
will remain active for a reset timeout period (tPRTO).  
POWER-OFF SEQUENCING  
The SMS66 can be programmed to perform Power-off  
sequencing in either the same order or reverse order  
of Power-on sequencing.  
While the SMS66 is in the Power-off sequencing mode  
the RST output is held active and the HEALTHY  
output is held inactive regardless of trigger sources.  
The Force Shutdown trigger option is also disabled  
while in this mode. Furthermore, the SMS66 will not  
respond to activity on the PWR_ON/OFF pin or to a  
Power-on I2C command during Power-off sequencing  
mode.  
FORCE SHUTDOWN  
The Force Shutdown operation brings all PUPX  
outputs to their inactive state. This operation is used  
for an emergency shutdown when there is not enough  
Power-off sequencing is the same as power-on  
sequencing and can be initiated by the PWR_ON/OFF  
pin, via I2C control or triggered by a fault condition on  
time to sequence the supplies off.  
The Force  
Shutdown operation shuts off all sequenced channels  
and waits for the supply voltages to drop below their  
respective OFF thresholds.  
any of the monitored inputs.  
Toggling the  
PWR_ON/OFF pin to its inactive state will initiate the  
Power-off sequence. To enable software control of  
the Power-off sequencing feature, the SMS66 offers  
an I2C command to initiate Power-off sequencing  
regardless of the state of the PWR_ON/OFF pin.  
Furthermore, Power-off sequencing can be initiated by  
a fault condition on a monitored input.  
A Force Shutdown operation can be initiated by any  
one of four events. The first two methods for initiating  
a Force Shutdown are always enabled. Simply taking  
the FS pin to its active state will initiate a Force  
Shutdown operation and maintain it until the pin is  
brought to its inactive state. An I2C Force Shutdown  
command allows the Force Shutdown operation to be  
initiated via software control. This I2C Force Shutdown  
command sets a volatile register bit that triggers a  
Once Power-off sequencing begins, the SMS66 will  
wait a Power-off delay time (tDPOFF) for any channel in  
the last sequence position (reverse order) and then  
deactivate the PUP outputs for those channels. The  
Power-off delay times are individually programmable  
for each channel. The SMS66 will then wait until all  
VMX inputs of the channels assigned to that sequence  
position are below their programmed OFF thresholds.  
At this point, the SMS66 will decrement to the next  
sequence position and begin to timeout the Power-off  
delay times for the associated channels. This process  
continues until all of channels in the sequence have  
turned off and are below their OFF thresholds. The  
status register reveals that all sequenced channels  
have turned off. The Power-off sequencing mode  
ends when all sequenced supplies are below their  
OFF thresholds.  
The programmable sequence termination timer can be  
used to protect against a stalled Power-off sequence.  
This timer resets itself at the beginning of each  
sequence position. All channels in the sequence  
position must go below their OFF threshold before the  
sequence termination timer times out (tSTT) or the  
sequence will terminate and all PUP outputs will be  
switched to their inactive state. This timer has four  
settings of OFF, 100ms, 200ms and 400ms. The  
sequence termination timer can be disabled separately  
for Power-off sequencing.  
Force Shutdown.  
This bit is cleared after all  
sequenced channels have dropped below their OFF  
voltage threshold. During Power-on and Power-off  
sequencing, the sequence termination timer can  
initiate a Force Shutdown operation.  
As described in the previous sections, the sequence  
termination timer triggers a Force Shutdown operation  
if it times out before the power supply voltages  
surpass their voltage thresholds.  
This Force  
Shutdown will remain active until all sequenced power  
supply channels have dropped below their OFF  
voltage threshold. While the SMS66 is in monitor  
mode, a programmed fault condition on any power  
supply channel or on the 12VIN or VDD inputs can  
trigger a Force Shutdown.  
A Force Shutdown  
resulting from this will remain active until all  
sequenced power supply channels have dropped  
below their OFF voltage threshold.  
Summit Microelectronics, Inc  
2070 1.0 7/16/03  
14  