APPLICATIONS INFORMATION (CONTINUED)  
POWER SEQUENCING  
The power-on sequencing begins with the power-  
on delay time of the channel(s) in sequence position 0.  
Once this delay has timed out the PUP will go active.  
At this point the supply connected to the VM input will  
begin to turn on. When this supply reaches its  
programmed threshold (under-voltage) and the PUP  
output has reached the level of VGG_CAP (high  
voltage PUP outputs only) the sequence position  
counter will change to position 1 and the power-on  
delay timer for the channel(s) in sequence position 1  
will begin. This will repeat until all channels that were  
programmed for sequencing have turned on and are  
not in fault conditions. Once sequencing is complete  
The SMS64 is a programmable controller for power  
supply sequencing. Up to six channels can be  
sequenced in any order with several delay options.  
In order for a power supply to be sequenced it must  
be enabled by a PUP output and monitored by the  
corresponding VM input. This channel must also be  
programmed to participate in the sequence and be  
assigned to a sequence position. If a channel is not  
programmed to participate in the sequence it should  
be assigned to the null sequence position (position 7)  
and the channel will act strictly as a voltage monitor.  
A sequence position is given to each channel as an  
order to the sequence.  
The sequence position  
RST_B# will clear after tPRTO  
.
assignments must begin at position 0 and must not  
skip positions. Also, multiple channels can be  
programmed into the same sequence position to  
enable more than one supply at a time. Note: If two  
or more channels with high voltage PUP outputs share  
the same sequence position their power-on delays  
must be either equal or differ by at least tSLEW (time it  
takes for the PUP output to slew from 0V to the level  
of VGG_CAP).  
Power-off sequencing can be initiated by a high to  
low transition on the PWR_ON/OFF pin, by writing to  
the power-off bit of the command register, or triggered  
off of a selected fault condition. The SMS64 can be  
configured to sequence the supplies off in the same  
order or reverse order of the power-on sequence.  
During the power-off sequence power-on commands  
as well as activity on the PWR_ON/OFF pin is ignored.  
The power-off sequencing begins with the power-  
off delay time of the channel(s) in the last sequence  
position of the power-on sequence (reverse order).  
Once this delay has timed out the PUP will turn off. At  
this point the supply connected to the VM input will  
begin to turn off. When this supply falls below 0.8V  
the sequence position counter will change to the next  
position and the power-off delay timer for the  
channel(s) in current sequence position will begin.  
This will repeat until all channels that were  
programmed for sequencing have turned off. At this  
point the voltage monitors will switch from the VM  
inputs to the VCC inputs to monitor for the precursor  
conditions to power-on sequencing. Note: With the  
OFF sensors disabled (configuration option) the  
SMS64 will immediately increment to the next  
sequence position instead of waiting until the VM  
inputs reach 0.8V.  
Each channel selected for sequencing is given a  
power-on and power-off delay. The power-on delay is  
a delay from the VM input of one channel going out of  
fault to the PUP output of another channel going  
active. The power-off delay is the delay from the VM  
input of one channel turning off to the PUP output of  
another channel that is turning off. The power-on and  
power-off delay options are 25ms, 50ms, 100ms and  
200ms. If the fast times option is selected in the  
configuration register, these delays are divided by 16  
(1.5625ms, 3.125ms, 6.25ms and 12.5ms).  
Before the SMS64 begins the power-on  
sequencing the voltage monitors are monitoring the  
VCC inputs. The power-on sequencing will not begin  
until all of the VCC inputs that are selected as  
precursors to power-on sequencing are out of their  
fault conditions, the ‘precondition qualifiers’.  
Power-on sequencing can be initiated by toggling  
the PWR_ON/OFF pin from low to high or by writing to  
the power-on bit of the command register. For  
automatic start-up the PWR_ON/OFF can be floated  
as the device receives power. Either of these will  
initiate the power-on sequence as soon as the  
precursor conditions are met. During the power-on  
sequence power-off commands as well as activity on  
the PWR_ON/OFF pin is ignored.  
FORCED SHUTDOWN  
The forced shutdown function is always enabled.  
This function is used to immediately turn off all PUP  
outputs when there is not enough time to perform a  
power-off sequence.  
Forced shutdown can be  
initiated by pulling the FS# pin low, by writing to the  
forced shutdown bit of the command register, or  
triggered off of a selected fault condition.  
Summit Microelectronics, Inc  
2060 2.22 10/09/03  