SMM665B  
Preliminary Information  
PIN DESCRIPTIONS  
Pin  
Pin  
Pin Name  
Pin Description  
Number Type  
1
I2C Bi-directional data line  
I2C Clock line  
DATA SDA  
2
CLK  
SCL  
The address pin is biased either to VDD_CAP or GND.  
When  
3
IN  
A2  
communicating with the SMM665B over the 2-wire bus A2 provides a  
mechanism for assigning a unique bus address.  
Programmable active high/low input. When asserted the RST output will be  
go active. When de-asserted the RST output will go inactive immediately  
after a reset timeout period (tPRTO) if there are no RST trigger sources active.  
This timeout period makes it suitable to use a pushbutton for manual reset.  
Programmable active high/low input signals the start of the power  
sequencing. When asserted the part will sequence the supplies on and  
when de-asserted the part will sequence the supplies off.  
Note: The SMM665B does not monitor for faults during sequencing. The  
PWR_ON/OFF pin is overridden by the I2C power on/off command. To get  
the pin to work again requires the part be given an I2C 'Clear' command (see  
page 16, “RESTART OF POWER-ON CASCADE SEQUENCING”).  
4
5
IN  
IN  
MR  
PWR_ON/OFF  
Programmable active high/low input. Force shutdown is used to immediately  
6
7
IN  
FS  
turn off all converter enable signals (PUP outputs) when a fault is detected.  
Programmable active high/low open drain Fault output. Active when a  
programmed fault condition exists on AIN1, AIN2, or the internal temperature  
sensor.  
OUT  
FAULT  
Programmable active high/low open drain Healthy output. Active when all  
programmed power supply inputs and monitored inputs are within OV and  
UV limits.  
Programmable active high/low open drain Reset output. Active when a  
programmed fault condition exists on any power supply inputs or monitored  
inputs or when MR is active. RST has a programmable timeout period with  
options for 0.64ms, 25ms, 100ms and 200ms.  
8
9
OUT  
OUT  
HEALTHY  
RST  
10  
11  
12  
General purpose monitored analog input  
General purpose monitored analog input  
Ground  
IN  
AIN1  
AIN2  
GND  
IN  
GND  
Voltage reference input used for A/D conversion where:  
(4XVREF_ADC) = Full Scale (FS) for VMA-F and VDD  
(12XVREF_ADC) = FS for 12VIN  
13  
IN  
VREF_ADC  
(2XVREF_ADC) = FS for AIN1 and AIN2.  
VREF_ADC can be connected to VREF_CNTL in most applications.  
Summit Microelectronics, Inc  
2089 1.1 10/20/04  