SMH4042A  
MONITORING POWER SUPPLY HEALTH  
MONITORINPUTS  
VCC vs. HST_3V_MON  
The VCC input is the supply input and in a CompactPCI  
application this pin must connect to an early power pin on  
the host connector. The HST_3V_MON input is strictly  
a voltage monitoring input, it is not a supply input. The  
operating supply voltage range on the VCC pin is 2.7V to  
5.5V, but it will only monitor a 5V supply. This is not an  
issuewithadualsupplyapplication. Butinasinglesupply  
application these two pins must be shorted and VSEL  
conditioned.  
The SMH4042A has a total of six comparators that are  
usedtomonitorthehealthofthehostplatformsuppliesand  
thecard-side(backend)voltages. Inhotswapapplications  
each supply going to the backend logic needs to be  
monitored at three points.  
The first point is at the source on the host connector, VCC  
and HST_3V_MON. If this voltage is not within specifi-  
cation, then the down stream sequencing of powering-on  
the backend logic will not proceed.  
The next stage (the CBI inputs) is one step closer to the  
backend logic to monitor the current flowing into the  
backend logic. This can not exceed the specification;  
however, If it does, then the SMH4042A must turn off the  
source to the backend logic.  
Programmable VTRIP Thresholds  
The host voltage monitors and the backend voltage  
monitors are programmable (by the factory) and provide  
anumberofoptionstotheenduser. TheVCCmonitorVTRIP  
level can be selected for either a 5% or 10% supply with  
The CARD_5V_MON and CARD_3V_MON inputs are default values of 4.25V or 4.625V. The HST_3V_MON  
used to sense the actual voltage level in the backend VTRIP levelcanbeprogrammedto2.65V, 2.8V, 2.95Vand  
logic. If either comparator detects a low voltage condition 3.1V.  
the backend logic will be placed in a reset condition  
The CARD_5V_MON and CARD_3V_MON thresholds  
(LOCAL_PCI_RST# asserted), but the VGATE outputs  
are set in relation to their corresponding host voltage  
will remain active so long as the host voltage and current  
monitor thresholds. Their offset can be either +50mV or  
sense are valid.  
–50mV. This allows the designer to select +50mV if they  
want a collapse in the backend voltage to trigger a local  
reset condition prior to the host supply collapsing and  
powering down the board without warning. Alternatively  
they can choose –50mV to trigger a board shutdown  
V
TRIP  
based on the host power supply falling out of spec.  
V
or  
CC  
HST_3V_MON  
Also see Figure 2  
t
VTPD  
DRVREN# &  
SGNL_VLD#  
t
CBTC  
CBI_3 or  
CBI_5  
VGATE3 &  
VGATE5  
FAULT#  
V
TRIP  
CARD_3V_MON or  
CARD_5V_MON  
VGATE3 &  
VGATE5  
t
VTR  
HEALTHY# &  
LOCAL_PCI_RST#  
PCI_RST#  
2070 Fig02  
2070 Fig03  
Figure 2. Loss-of-Voltage Timing Sequence  
Figure 3. Circuit Breaker Timing Sequence  