 浏览型号STM32F103R4T6XXX的Datasheet PDF文件第60页浏览型号STM32F103R4T6XXX的Datasheet PDF文件第61页浏览型号STM32F103R4T6XXX的Datasheet PDF文件第62页浏览型号STM32F103R4T6XXX的Datasheet PDF文件第63页浏览型号STM32F103R4T6XXX的Datasheet PDF文件第65页浏览型号STM32F103R4T6XXX的Datasheet PDF文件第66页浏览型号STM32F103R4T6XXX的Datasheet PDF文件第67页浏览型号STM32F103R4T6XXX的Datasheet PDF文件第68页  
Electrical characteristics  
Equation 1: R  
STM32F103x4, STM32F103x6  
max formula:  
AIN  
TS  
RAIN ------------------------------------------------------------- – RADC  
fADC CADC ln2N + 2  
The formula above (Equation 1) is used to determine the maximum external impedance allowed for an  
error below 1/4 of LSB. Here N = 12 (from 12-bit resolution).  
(1)  
Table 46.  
R
max for f  
= 14 MHz  
AIN  
ADC  
Ts (cycles)  
tS (µs)  
RAIN max (k)  
1.5  
0.11  
0.4  
7.5  
0.54  
0.96  
2.04  
2.96  
3.96  
5.11  
17.1  
5.9  
13.5  
28.5  
41.5  
55.5  
71.5  
239.5  
11.4  
25.2  
37.2  
50  
NA  
NA  
1. Based on characterization, not tested in production.  
(1) (2)  
Table 47. ADC accuracy - limited test conditions  
Symbol  
Parameter  
Test conditions  
Typ  
Max(3)  
Unit  
ET  
EO  
EG  
ED  
EL  
Total unadjusted error  
Offset error  
1.3  
1
2
fPCLK2 = 56 MHz,  
fADC = 14 MHz, RAIN < 10 k,  
VDDA = 3 V to 3.6 V  
TA = 25 °C  
1.5  
1.5  
1
Gain error  
0.5  
0.7  
0.8  
LSB  
Differential linearity error  
Integral linearity error  
Measurements made after  
ADC calibration  
1.5  
1. ADC DC accuracy values are measured after internal calibration.  
2. ADC Accuracy vs. Negative Injection Current: Injecting negative current on any of the standard (non-  
robust) analog input pins should be avoided as this significantly reduces the accuracy of the conversion  
being performed on another analog input. It is recommended to add a Schottky diode (pin to ground) to  
standard analog pins which may potentially inject negative current.  
Any positive injection current within the limits specified for IINJ(PIN) and IINJ(PIN) in Section 5.3.12 does not  
affect the ADC accuracy.  
3. Based on characterization, not tested in production.  
64/80  
Doc ID 15060 Rev 3  
 复制成功!