STM32F103x8, STM32F103xB
Table 30. EMS characteristics
Symbol
Parameter
Electrical characteristics
Conditions
Level/
Class
2B
V
FESD
V
DD
½3.3
V, T
A
½+25
°C,
Voltage limits to be applied on any I/O pin to
f
HCLK
½
72 MHz
induce a functional disturbance
conforms to IEC 61000-4-2
Fast transient voltage burst limits to be
applied through 100 pF on V
DD
and V
SS
pins to induce a functional disturbance
V
DD
½3.3
V, T
A
½+25
°C,
f
HCLK
½72
MHz
conforms to IEC 61000-4-4
V
EFTB
4A
Designing hardened software to avoid noise problems
EMC characterization and optimization are performed at component level with a typical
application environment and simplified MCU software. It should be noted that good EMC
performance is highly dependent on the user application and the software in particular.
Therefore it is recommended that the user applies EMC software optimization and
prequalification tests in relation with the EMC level requested for his application.
Software recommendations
The software flowchart must include the management of runaway conditions such as:
Corrupted program counter
Unexpected reset
Critical Data corruption (control registers...)
Prequalification trials
Most of the common failures (unexpected reset and program counter corruption) can be
reproduced by manually forcing a low state on the NRST pin or the Oscillator pins for 1
second.
To complete these trials, ESD stress can be applied directly on the device, over the range of
specification values. When unexpected behavior is detected, the software can be hardened
to prevent unrecoverable errors occurring (see application note AN1015).
Electromagnetic Interference (EMI)
The electromagnetic field emitted by the device are monitored while a simple application is
executed (toggling 2 LEDs through the I/O ports). This emission test is compliant with
IEC 61967-2 standard which specifies the test board and the pin loading.
Table 31. EMI characteristics
Symbol Parameter
Conditions
Monitored
frequency band
0.1 to 30 MHz
30 to 130 MHz
130 MHz to 1GHz
SAE EMI Level
Max vs. [f
HSE
/f
HCLK
]
8/48 MHz 8/72 MHz
12
22
23
4
12
19
29
4
-
dBµV
Unit
S
EMI
V
DD
½3.3
V, T
A
½25
°C,
LQFP100 package
Peak level
compliant with
IEC 61967-2
DocID13587 Rev 16
59/105
104