M95040, M95020, M95010
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 8. Operating Conditions (M950x0)
Symbol
Parameter
Min.
4.5
Max.
5.5
Unit
V
V
CC
Supply Voltage
Ambient Operating Temperature (Device Grade 6)
Ambient Operating Temperature (Device Grade 3)
–40
–40
85
°C
°C
TA
125
Table 9. Operating Conditions (M950x0-W)
Symbol
Parameter
Min.
2.5
Max.
5.5
Unit
V
V
CC
Supply Voltage
Ambient Operating Temperature (Device Grade 6)
Ambient Operating Temperature (Device Grade 3)
–40
–40
85
°C
°C
TA
125
Table 10. Operating Conditions (M950x0-R)
Symbol
Parameter
Min.
1.8
Max.
5.5
Unit
V
V
CC
Supply Voltage
Ambient Operating Temperature
TA
–40
85
°C
Table 11. AC Measurement Conditions
Symbol
Parameter
Min.
Max.
Unit
pF
ns
V
C
Load Capacitance
100
L
Input Rise and Fall Times
50
0.2V to 0.8V
Input Pulse Voltages
CC
CC
CC
0.3V to 0.7V
Input and Output Timing Reference Voltages
V
CC
Note: Output Hi-Z is defined as the point where data out is no longer driven.
Figure 15. AC Measurement I/O Waveform
Input Levels
Input and Output
Timing Reference Levels
0.8V
CC
CC
0.7V
CC
0.3V
CC
0.2V
AI00825B