M74HC266
CAPACITIVE CHARACTERISTICS
Test Condition
Symbol
Parameter
V
CC
(V)
5.0
5.0
T
A
= 25°C
Min.
Typ.
5
20
Max.
10
Value
-40 to 85°C
Min.
Max.
10
-55 to 125°C
Min.
Max.
10
pF
pF
Unit
C
IN
C
PD
Input Capacitance
Power Dissipation
Capacitance (note
1)
1) C
PD
is defined as the value of the IC’s internal equivalent capacitance which is calculated from the operating current consumption without
load. (Refer to Test Circuit). Average operating current can be obtained by the following equation. I
CC(opr)
= C
PD
x V
CC
x f
IN
+ I
CC
/4 (per gate)
TEST CIRCUIT
C
L
= 50pF or equivalent (includes jig and probe capacitance)
R
T
= Z
OUT
of pulse generator (typically 50Ω)
WAVEFORM : PROPAGATION DELAY TIME
(f=1MHz; 50% duty cycle)
4/8