 浏览型号M29W320DT70N1T的Datasheet PDF文件第8页浏览型号M29W320DT70N1T的Datasheet PDF文件第9页浏览型号M29W320DT70N1T的Datasheet PDF文件第10页浏览型号M29W320DT70N1T的Datasheet PDF文件第11页浏览型号M29W320DT70N1T的Datasheet PDF文件第13页浏览型号M29W320DT70N1T的Datasheet PDF文件第14页浏览型号M29W320DT70N1T的Datasheet PDF文件第15页浏览型号M29W320DT70N1T的Datasheet PDF文件第16页  
M29W320DT, M29W320DB
Note that if V
PP
/WP is at V
IL
, then the 16 KByte
outermost boot block will remain protect even if RP
is at V
ID
.
After a Hardware Reset, Bus Read and Bus Write
operations cannot begin until Ready/Busy be-
comes high-impedance. See Table 14. and Figure
acteristics.
The use of an open-drain output allows the Ready/
Busy pins from several memories to be connected
to a single pull-up resistor. A Low will then indicate
that one, or more, of the memories is busy.
Byte/Word Organization Select (BYTE).
The
Byte/Word Organization Select pin is used to
switch between the x8 and x16 Bus modes of the
memory. When Byte/Word Organization Select is
Low, V
IL
, the memory is in x8 mode, when it is
High, V
IH
, the memory is in x16 mode.
pro-
V
CC
Supply Voltage (2.7V to 3.6V).
V
CC
vides the power supply for all operations (Read,
Program and Erase).
The Command Interface is disabled when the V
CC
Supply Voltage is less than the Lockout Voltage,
V
LKO
. This prevents Bus Write operations from ac-
cidentally damaging the data during power up,
power down and power surges. If the Program/
Erase Controller is programming or erasing during
this time then the operation aborts and the memo-
ry contents being altered will be invalid.
A 0.1µF capacitor should be connected between
the V
CC
Supply Voltage pin and the V
SS
Ground
pin to decouple the current surges from the power
supply. The PCB track widths must be sufficient to
carry the currents required during Program and
Erase operations, I
CC3
.
V
SS
Ground.
V
SS
is the reference for all voltage
measurements.