M27C512
DC and AC parameters
5
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC Characteristic tables that
follow are derived from tests performed under the Measurement Conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 6.
AC measurement conditions
High Speed
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
≤
10ns
0 to 3V
1.5V
Standard
≤
20ns
0.4V to 2.4V
0.8V and 2V
Figure 5.
Testing input/output waveform
High Speed
3V
1.5V
0V
Standard
2.4V
2.0V
0.8V
AI01822
0.4V
Figure 6.
AC Testing Load Circuit
1.3V
1N914
3.3kΩ
DEVICE
UNDER
TEST
CL
OUT
CL = 30pF for High Speed
CL = 100pF for Standard
CL includes JIG capacitance
AI01823B
11/22