DC and AC parameters
M27C2001
4
DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 5, Operating and AC Measurement Conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 5.
AC Measurement conditions
High Speed
Standard
Input Rise and Fall Times
≤10ns
0 to 3V
1.5V
≤20ns
Input Pulse Voltages
0.4V to 2.4V
0.8V and 2V
Input and Output Timing Ref. Voltages
(1)
Table 6.
Symbol
Capacitance
(T = 25°C, f = 1 MHz)
A
Parameter
Test Condition
= 0V
Min
Max
Unit
C
C
Input Capacitance
Output Capacitance
V
6
pF
pF
IN
IN
V
= 0V
12
OUT
OUT
1. Sampled only, not 100% tested
Figure 6.
AC Testing Input Output Waveform
High Speed
3V
1.5V
0V
Standard
2.4V
2.0V
0.8V
0.4V
AI01822
13/25