M24C16, M24C08, M24C04, M24C02, M24C01
Table 17. AC Characteristics (M24Cxx-R)
Test conditions specified in Table 8. and Table 7.
4
4
Symbol
fC
Alt.
fSCL
Parameter
Clock Frequency
Min.
Max.
Unit
kHz
ns
Min.
Max.
100
400
tCHCL
tCLCH
tHIGH
tLOW
tF
Clock Pulse Width High
Clock Pulse Width Low
SDA Fall Time
4000
4700
20
600
1300
20
ns
2
300
300
900
ns
tDL1DL2
tDXCX
tCLDX
tCLQX
tSU:DAT
tHD:DAT
tDH
Data In Set Up Time
Data In Hold Time
Data Out Hold Time
250
0
100
0
ns
ns
200
200
ns
Clock Low to Next Data Valid (Access
Time)
3
tAA
200
3500
200
ns
tCLQV
1
tSU:STA
tHD:STA
tSU:STO
Start Condition Set Up Time
Start Condition Hold Time
Stop Condition Set Up Time
4700
4000
4000
600
600
600
ns
ns
ns
tCHDX
tDLCL
tCHDH
Time between Stop Condition and
Next Start Condition
tDHDL
tW
tBUF
tWR
4700
1300
ns
Write Time
10
10
ms
Note: 1. For a reSTART condition, or following a Write cycle.
2. Sampled only, not 100% tested.
3. To avoid spurious START and STOP conditions, a minimum delay is placed between SCL=1 and the falling or rising edge of SDA.
4. 100kHz clock frequency is offered on the standard device. 400kHz clock frequency is offered on new products bearing the Process
Identification letter “W” or “G” on the package, as described in Table 24..
19/29