L7800
ELECTRICAL CHARACTERISTICS FOR L7820 (refer to the test circuits, Tj = -55 to 150 oC,
Vi = 28V, Io = 500 mA, Ci = 0.33 µF, Co = 0.1 µF unlessotherwise specified)
Symbol
Vo
Parameter
Output Voltage
Output Voltage
Test Conditions
Min.
19.2
19
Typ.
20
Max.
20.8
21
Unit
V
Tj = 25 oC
Vo
Io = 5 mA to 1 A Po ≤ 15 W
20
V
Vi = 24 to 35 V
∆Vo* Line Regulation
∆Vo* Load Regulation
Vi = 22.5 to 35 V Tj = 25 oC
200
100
mV
mV
Vi = 26 to 32 V Tj = 25 oC
Io = 5 to 1500 mA
Tj = 25 oC
200
100
mV
mV
Io = 250 to 750 mA T = 25 oC
j
Id
Quiescent Current
Tj = 25 oC
6
mA
mA
∆Id
∆Id
Quiescent Current Change
Quiescent Current Change
Output Voltage Drift
Io = 5 to 1000 mA
Vi = 24 to 35 V
Io = 5 mA
0.5
0.8
mA
mV/oC
∆Vo
∆T
2.5
eN
Output Noise Voltage
B = 10Hz to 100KHz Tj = 25 oC
40
µV/VO
dB
V
SVR Supply Voltage Rejection
Vi = 24 to 35 V
f = 120 Hz
58
Vd
Ro
Isc
Dropout Voltage
Io = 1 A
Tj = 25 oC
2
2.5
Output Resistance
f = 1 KHz
Vi = 35 V
Tj = 25 oC
24
mΩ
A
Short Circuit Current
Short Circuit Peak Current
Tj = 25 oC
0.75
2.2
1.2
3.3
Iscp
1.3
A
ELECTRICAL CHARACTERISTICS FOR L7824 (refer to the test circuits, Tj = -55 to 150 oC,
Vi = 33V, Io = 500 mA, Ci = 0.33 µF, Co = 0.1 µF unlessotherwise specified)
Symbol
Parameter
Output Voltage
Output Voltage
Test Conditions
Min.
Typ.
Max.
Unit
V
Vo
Tj = 25 oC
23
24
25
Vo
Io = 5 mA to 1 A Po ≤ 15 W
22.8
24
25.2
V
Vi = 28 to 38 V
∆Vo* Line Regulation
∆Vo* Load Regulation
Vi = 27 to 38 V Tj = 25 oC
240
120
mV
mV
Vi = 30 to 36 V Tj = 25 oC
Io = 5 to 1500 mA
Tj = 25 oC
240
120
mV
mV
Io = 250 to 750 mA T = 25 oC
j
Id
Quiescent Current
Tj = 25 oC
6
mA
mA
∆Id
∆Id
Quiescent Current Change
Quiescent Current Change
Output Voltage Drift
Io = 5 to 1000 mA
Vi = 28 to 38 V
Io = 5 mA
0.5
0.8
mA
mV/oC
∆Vo
∆T
3
eN
Output Noise Voltage
B = 10Hz to 100KHz Tj = 25 oC
40
µV/VO
dB
V
SVR Supply Voltage Rejection
Vi = 28 to 38 V
f = 120 Hz
56
Vd
Ro
Isc
Dropout Voltage
Io = 1 A
Tj = 25 oC
2
2.5
Output Resistance
f = 1 KHz
Vi = 35 V
Tj = 25 oC
28
mΩ
A
Short Circuit Current
Short Circuit Peak Current
Tj = 25 oC
0.75
2.2
1.2
3.3
Iscp
1.3
A
* Load and line regulation are specified at constant junction temperature. Changes in Vo due to heating effects must be taken into account