L7800 SERIES
Table 13: Electrical Characteristics Of L7852C
(refer to the test circuits, T
J
= 0 to 125°C, V
I
= 10V,
I
O
= 500 mA, C
I
= 0.33 µF, C
O
= 0.1 µF unless otherwise specified).
Symbol
V
O
V
O
∆V
O
(*)
∆V
O
(*)
I
d
∆I
d
Parameter
Output Voltage
Output Voltage
Line Regulation
Load Regulation
Quiescent Current
Quiescent Current Change
T
J
= 25°C
I
O
= 5 mA to 1 A
V
I
= 8 to 20 V
V
I
= 7 to 25 V
V
I
= 8 to 12 V
I
O
= 5 mA to 1.5 A
I
O
= 250 to 750 mA
T
J
= 25°C
I
O
= 5 mA to 1 A
V
I
= 7 to 25 V
∆V
O
/∆T Output Voltage Drift
eN
SVR
V
d
R
O
I
sc
I
scp
Output Noise Voltage
Supply Voltage Rejection
Dropout Voltage
Output Resistance
Short Circuit Current
Short Circuit Peak Current
I
O
= 5 mA
B =10Hz to 100KHz
V
I
= 8 to 18 V
I
O
= 1 A
f = 1 KHz
V
I
= 35 V
T
J
= 25°C
T
J
= 25°C
T
J
= 25°C
T
J
= 25°C
f = 120Hz
61
2
17
0.75
2.2
-1
42
P
O
≤
15W
T
J
= 25°C
T
J
= 25°C
T
J
= 25°C
T
J
= 25°C
Test Conditions
Min.
5.0
4.95
Typ.
5.2
5.2
3
1
Max.
5.4
5.45
105
52
105
52
8
0.5
1.3
mV/°C
µV/V
O
dB
V
mΩ
A
A
mA
mA
mV
Unit
V
V
mV
(*) Load and line regulation are specified at constant junction temperature. Changes in V
O
due to heating effects must be taken into account
separately. Pulse testing with low duty cycle is used.
Table 14: Electrical Characteristics Of L7806C
(refer to the test circuits, T
J
= 0 to 125°C, V
I
= 11V,
I
O
= 500 mA, C
I
= 0.33 µF, C
O
= 0.1 µF unless otherwise specified).
Symbol
V
O
V
O
∆V
O
(*)
∆V
O
(*)
I
d
∆I
d
Parameter
Output Voltage
Output Voltage
Line Regulation
Load Regulation
Quiescent Current
Quiescent Current Change
T
J
= 25°C
I
O
= 5 mA to 1 A
V
I
= 8 to 21 V
V
I
= 8 to 25 V
V
I
= 9 to 13 V
I
O
= 5 mA to 1.5 A
I
O
= 250 to 750 mA
T
J
= 25°C
I
O
= 5 mA to 1 A
V
I
= 8 to 25 V
∆V
O
/∆T Output Voltage Drift
eN
SVR
V
d
R
O
I
sc
I
scp
Output Noise Voltage
Supply Voltage Rejection
Dropout Voltage
Output Resistance
Short Circuit Current
Short Circuit Peak Current
I
O
= 5 mA
B =10Hz to 100KHz
V
I
= 9 to 19 V
I
O
= 1 A
f = 1 KHz
V
I
= 35 V
T
J
= 25°C
T
J
= 25°C
T
J
= 25°C
T
J
= 25°C
f = 120Hz
59
2
19
0.55
2.2
-0.8
45
P
O
≤
15W
T
J
= 25°C
T
J
= 25°C
T
J
= 25°C
T
J
= 25°C
Test Conditions
Min.
5.75
5.7
Typ.
6
6
Max.
6.25
6.3
120
60
120
60
8
0.5
1.3
mV/°C
µV/V
O
dB
V
mΩ
A
A
mA
mA
mV
Unit
V
V
mV
(*) Load and line regulation are specified at constant junction temperature. Changes in V
O
due to heating effects must be taken into account
separately. Pulse testing with low duty cycle is used.
10/34