Electrical characteristics
L78xx, L78xxC, L78xxAB, L78xxAC
Refer to the test circuits, TJ = 0 to 125 °C, VI = 23 V, IO = 500 mA, CI = 0.33 µF, CO = 0.1 µF
unless otherwise specified.
Table 19. Electrical characteristics of L7815C
Symbol
Parameter
Output voltage
Test conditions
Min.
Typ.
Max.
Unit
VO
VO
VO
TJ = 25°C
14.5
14.25
14.25
15
15
15
15.6
15.75
15.75
300
150
300
150
8
V
V
V
Output voltage
Output voltage
IO = 5 mA to 1 A, VI = 17.5 to 28 V
IO = 1 A, VI = 28 to 30 V, TJ = 25°C
VI = 17.5 to 30 V, TJ = 25°C
(1)
ΔVO
Line regulation
mV
VI = 20 to 26 V, TJ = 25°C
I
O = 5 mA to 1.5 A, TJ = 25°C
(1)
ΔVO
Load regulation
mV
mA
mA
IO = 250 to 750 mA, TJ = 25°C
TJ = 25°C
Id
Quiescent current
I
O = 5 mA to 1A
0.5
ΔId
Quiescent current change
VI = 17.5 to 30 V
1
ΔVO/ΔT Output voltage drift
IO = 5 mA
-1
mV/°C
µV/VO
dB
eN
SVR
Vd
Output noise voltage
Supply voltage rejection
Dropout voltage
B = 10 Hz to 100kHz, TJ = 25°C
VI = 18.5 to 28.5 V, f = 120 Hz
IO = 1 A, TJ = 25°C
f = 1 kHz
90
54
2
V
RO
Isc
Output resistance
19
mΩ
A
Short circuit current
VI = 35 V, TJ = 25°C
0.23
2.2
Iscp
Short circuit peak current TJ = 25°C
A
1. Load and line regulation are specified at constant junction temperature. Changes in V due to heating effects must be
O
taken into account separately. Pulse testing with low duty cycle is used.
24/57
Doc ID 2143 Rev 30