L78xx, L78xxC, L78xxAB, L78xxAC  
Electrical characteristics  
VI = 11 V, IO = 1 A, TJ = 0 to 125 °C (L7806AC), TJ = -40 to 125 °C (L7806AB), unless  
otherwise specified.  
Table 6.  
Symbol  
Electrical characteristics of L7806A  
Parameter  
Output voltage  
Test conditions  
Min.  
Typ.  
Max.  
Unit  
VO  
VO  
VO  
TJ = 25°C  
5.88  
5.76  
5.76  
6
6
6.12  
6.24  
6.24  
60  
V
Output voltage  
Output voltage  
IO = 5 mA to 1 A, VI = 8.6 to 19 V  
IO = 1 A, VI = 19 to 21 V, TJ = 25°C  
VI = 8.6 to 25 V, IO = 500 mA, TJ = 25°C  
VI = 9 to 13 V  
V
6
V
9
mV  
mV  
mV  
mV  
11  
3
60  
(1)  
ΔVO  
Line regulation  
VI = 9 to 13 V, TJ = 25°C  
30  
VI = 8.3 to 21 V, TJ = 25°C  
IO = 5 mA to 1 A  
9
60  
25  
30  
10  
4.3  
100  
100  
50  
(1)  
ΔVO  
Load regulation  
IO = 5 mA to 1.5 A, TJ = 25°C  
mV  
IO = 250 to 750 mA  
TJ = 25°C  
6
mA  
mA  
mA  
mA  
mA  
dB  
Iq  
Quiescent current  
6
VI = 9 to 24 V, IO = 500 mA  
0.8  
0.8  
0.5  
ΔIq  
Quiescent current change VI = 8.6 to 21 V, TJ = 25°C  
IO = 5 mA to 1 A  
SVR  
Vd  
Supply voltage rejection  
Dropout voltage  
VI = 9 to 19 V, f = 120 Hz, IO = 500 mA  
65  
2
IO = 1 A, TJ = 25°C  
TA = 25°C, B =10 Hz to 100 kHz  
f = 1 kHz  
V
eN  
RO  
Isc  
Output noise voltage  
Output resistance  
10  
µV/VO  
mΩ  
A
17  
Short circuit current  
VI = 35 V, TA = 25°C  
0.2  
2.2  
-0.8  
Iscp  
Short circuit peak current TJ = 25°C  
A
ΔVO/ΔT Output voltage drift  
mV/°C  
1. Load and line regulation are specified at constant junction temperature. Changes in V due to heating effects must be  
O
taken into account separately. Pulse testing with low duty cycle is used.  