Description  
L6699  
1
Description  
The L6699 is a double-ended controller specific to series-resonant half bridge topology.  
Both LLC and LCC configurations are supported. It provides symmetrical complementary  
duty cycle: the high-side switch and the low-side switch are driven ON/OFF 180° out-of-  
phase for exactly the same time. Output voltage regulation is obtained by modulating the  
operating frequency. The deadtime inserted between the turn-off of one switch and the turn-  
on of the other one is automatically adjusted to best fit the transition times of the half bridge  
midpoint. To drive the high-side switch with the bootstrap approach, the IC incorporates a  
high voltage floating structure able to withstand more than 600 V with a synchronous-driven  
high voltage DMOS that replaces the external fast-recovery bootstrap diode.  
The IC enables the user to set the operating frequency range of the converter by means of a  
high-accuracy externally programmable oscillator.  
At startup, in addition to the traditional frequency-shift soft-start (the switching frequency  
starts from a preset maximum value and then decays as far as the steady-state value  
determined by the control loop), a proprietary circuit controls the half bridge to prevent hard-  
switching from occurring in the initial cycles because of the unbalance in the V·s applied to  
the transformer.  
At light load the IC can be forced to enter a controlled burst-mode operation that keeps the  
converter input consumption as low as possible.  
IC protection functions include a current sense input for OCP with frequency shift and  
delayed shutdown with automatic restart. Fast shutdown with automatic restart occurs if this  
first-level protection cannot control the primary current. Additionally, the IC prevents the  
converter from working in or too close to the capacitive mode, to guarantee soft-switching. A  
latched disable input (DIS) can be used to implement OTP and/or OVP. The combination of  
these protection features offers the highest degree of safety.  
Other functions include a not-latched active-low disable input with current hysteresis, useful  
for power sequencing or for brownout protection, and an interface with the PFC controller  
that enables the switching-off of the pre-regulator during fault conditions or during burst-  
mode operation.  
4/38  
Doc ID 022835 Rev 2  