BTA/BTB24, BTA25, BTA26
and T25 Series
25A TRIAC
S
SNUBBERLESS™ & STANDARD
MAIN FEATURES:
Symbol
I
T(RMS)
V
DRM
/V
RRM
I
GT (Q
1
)
Value
25
600 and 800
35 to 50
Unit
A
V
mA
A1
A2
G
A2
G
A2
A2
A1
A1
A2
G
DESCRIPTION
Available either in through-hole of surface and T25
mount packages, the BTA/BTB24-25-26 triac
series is suitable for general purpose AC power
switching. They can be used as an ON/OFF
function in applications such as static relays,
heating regulation, water heaters, induction motor
starting circuits...or for phase control operation in
high power motor speed controllers, soft start
circuits...The snubberless versions (BTA/BTB...W
and T25 series) are specially recommended for
use on inductive loads, thanks to their high
commutation performances.
By using an internal ceramic pad, the BTA series
provides voltage insulated tab (rated at 2500V
RMS) complying with UL standards (File ref.:
E81734).
ABSOLUTE MAXIMUM RATINGS
Symbol
I
T(RMS)
Parameter
RMS on-state current (full sine wave)
TO-220AB
Insulated
(BTA24)
A1 A2
G
A2
TO-220AB
(BTB24)
A1
G
A2
D
2
PAK
(T25G)
A1 A2
G
RD91
(BTA25)
TOP3
Insulated
(BTA26)
Value
Tc = 100°C
Tc = 90°C
Tc = 75°C
t = 16.7 ms
t = 20 ms
25
Unit
A
I
TSM
It
dI/dt
Non repetitive surge peak on-state
current (full cycle, Tj initial = 25°C)
I t Value for fusing
Critical rate of rise of on-state current
I
G
= 2 x I
GT
, tr
≤
100 ns
D PAK
TO-220AB
RD91
TOP3 Ins.
TO-220AB Ins.
F = 60 Hz
F = 50 Hz
260
250
450
A
As
A/µs
V
A
W
°C
1/9
tp = 10 ms
F = 120 Hz
tp = 10 ms
tp = 20
µs
Tj = 125°C
Tj = 25°C
Tj = 125°C
Tj = 125°C
50
V
DRM
/V
RRM
+ 100
V
DSM
/V
RSM
Non repetitive surge peak off-state
voltage
I
GM
P
G(AV)
T
stg
T
j
Peak gate current
Average gate power dissipation
Storage junction temperature range
Operating junction temperature range
4
1
- 40 to + 150
- 40 to + 125
September 2000 - Ed: 3