SPECIFICATIONS
FIGURE 1
CX1V TYPICAL MOTIONAL RESISTANCE (R1)
Specifications are typical at 25oC unless otherwise noted.
Specifications are subject to change without notice.
Frequency Range
300
200
10 kHz to 600 kHz
(see below)
100
Calibration Tolerance1
Motional Resistance (R1)
Figure 1
MAX.: 2x Typ.@10-169.9 kHz
50
2.5x Typ.@170-600 kHz
Motional Capacitance (C1) Figure 2
20
10
Quality Factor (Q)
Figure 3
Min. is 0.25x Typ.
2.0 pF MAX.
5
2
Shunt Capacitance (C0)
Drive Level
0.5
1.0
µ
µ
W MAX.@10-24.9 kHz
W MAX.@ 25-600 kHz
10
20
50
100 200
600
Turning Point (T )2
Figure 4
Frequency (kHz)
O
Temperature Coefficient (k) -0.035 ppm/0C2
FIGURE 2
CX1V TYPICAL MOTIONAL CAPACITANCE (C1)
Aging, first year
Shock, survival3
Vibration, survival3
Operating Temperature
5ppm MAX.
5
1,000 G peak 1ms, 1/2 sine
20 G RMS 10-2,000 Hz
-10oC to +70oC (Commercial)
-40oC to +85oC (Industrial)
-55oC to +125oC (Military)
-55oC to +125oC
2
1.0
Storage Temperature
Max Process Temperature See package handling
0.5
10
20
50
100 200
600
1. Tighter frequency calibration available.
2. Other turning point available.
3. Higher shock and vibration available.
Frequency (kHz)
FIGURE 3
CX1V TYPICAL QUALITY FACTOR (Q)
300
200
Load Capacitance (CL), Used to Calibrate CX-1V
(other CL available)
100
Frequency
Load
Frequency
Load
50
Range
(kHz)
Capacitance
(pF)
Range
(kHz)
Capacitance
(pF)
20
10
20
50
100 200
600
Frequency (kHz)
FIGURE 4
CX1V TYPICAL TURNING POINT TEMP. (T0)
10-15.9
16-24.9
25-54.9
11
10
9
55-99.9
100-179.9
180-600
8
5
4
+80
+70
+60
+50
+40
+30
+20
+10
0
o
CX1V Standard Calibration Tolerance at 25 C
Frequency Range (kHz)
10-74.9
30 ppm
75-169.9
50 ppm
170-249.9
100 ppm
250-600
200 ppm
-10
-20
HOW TO ORDER CX1V LEADED CRYSTALS
10
20
50
100 200
600
CX1V
S
03
32.768K,
30
/
I
Frequency (kHz)
Frequency Calibration Operating Temp. Range:
C = -10OC to +70OC
“S” if special
or custom
design. Blank
if Std.
Side Leads
03 = Non-
RoHS
Compliant
05 = RoHS
Compliant
Note: Frequency (f) deviation from frequency (f ) @ turning point
o
K = kHz
Tolerance*
@ 25OC
(in ppm)
temperature (T ):
I
= -40OC to +85OC
= k(T-T )2
0
f-f0
M = -55OC to +125OC
S = Customer Specified
0
f0
PACKAGING FOR LEADED CRYSTALS
CX1V - Tray Pack (Standard)
*The above table provides the best calibration tolerance available
for each frequency range at 25°C.
10101 - Rev C
STATEK CORPORATION 512 N. MAIN ST., ORANGE, CA 92868 714-639-7810 FAX: 714-997-1256 www.statek.com