SCW16□3US Series
High Flux Type LED
Reliability Testing Result
Reliability Testing
Applicable
Standard
EIAJ ED-
Testing Conditions
Duration
Failure
0/16
0/16
0/16
0/16
0/16
0/16
Result
Room Temp.
Operating Life
Ta = 25℃, IF = Maxium Rated Current
1,000 h
4701/100(101)
High Temp.
Operating Life
EIAJ ED-
4701/100(101)
F
Ta = Maximum Rated Operating Temp., I = 275mA
1,000 h
1,000 h
Low Temp.
Operating Life
EIAJ ED-
4701/100(101)
Ta = -40℃, IF = Maxium Rated Current
Wet High Temp.
Operating Life
EIAJ ED-
4701/100(102)
F
Ta = 60℃, 90%, I = Maxium Rated Current
1,000 h
EIAJ ED-
4701/100(105)
EIAJ ED-
Ta = -40℃ ~ Maximum Rated Storage Temp.
(each 30min.)
Preheating : 150 ~ 180℃(120s Max.)
Operation Heating : 230℃(40s) → 260℃(5s)
Temperature Cycling
1,000 cycles
5 times
Resistance to
Soldering Heat
4701/300(301)
Failure Criteria
Items
Symbols
Conditions
Failure criteria
F
I Value of each product
Luminous Intensity
Iv
Testing Min. Value < Spec. Min. Value x 0.7
Testing Max. Value ≧ Spec. Max. Value x 1.2
Testing Max. Value ≧ Spec. Max. Value x 2.5
Luminous intensity
F
I Value of each product
F
Forward Voltage
Reverse Current
V
Forward Voltage
R
V = Maximum Rated
R
I
Reverse Voltage V
Occurrence of notable decoloration,
deformation and cracking
Cosmetic Appearance
-
-
Page 15
2009.5.30