KUA0055A
Reflector Sensor
Reliability Testing Result
Applicable
Reliability Testing Result
Standard
Testing Conditions
Ta = 85℃, RH = 85%, VCC = 5V
Duration
1,000 h
1,000 h
1,000 h
1,000 h
200 cycles
30min
Failure
0/5
Wet High Temp.
Operaing Life
EIAJ ED-
4701/100(102)
Wet High Temp.
Storage Life
EIAJ ED-
4701/100(103)
Ta = 85℃, 95%
0/5
High Temp.
EIAJ ED-
Ta = 85℃, VCC = 5V
Ta = -10℃, VCC = 5V
-40℃ ~ 85℃
0/5
Operating Life
4701/100(101)
Low Temp.
EIAJ ED-
0/5
Operating Life
4701/100(101)
EIAJ ED-
4701/200/(203)
Thermal Shock
0/5
9.8m/s2 (1G), 10 ~ 55 ~ 10Hz sweep for 60s,
XYZ each direction(State of packing)
Vibration,
EIAJ ED-
0/3
Variable Frequency
4701/400(403)
EIAJ ED-
4701/400(404)
294m/s2 (30G), XYZ each direction (State of packing)
Shock
3 times
0/3
EIAJ ED-
Pull : 20N 5s
Terminal Strength
-
0/Each 5
0/3
4701/400(401) Bend : 10N 5s
Electric Static Discharge
(ESD)
EIAJ ED-
4701/300(304)
once each
terminal
C = 100pF, R = 1.5KΩ, ±1KV
Failure Criteria
Items
Failure criteria
The Rated Values of Electro Characteristics is satisfied.
Occurrence of notable decoloration, deformation and cracking
Electro Characteristics
Cosmetic Appearance
Page 4
2007.8.31