□□1111R
Surface Mount IRED/Reverse Mount Type
Technical Data(DNK)
Power Dissipation vs. Ambient Temperature
Derating
Ambient Temperature vs. Maximum Forward Curren
Pulse Width tw≦100μsec
90
80
70
60
50
40
30
20
10
0
350
300
250
200
150
100
50
Duty=1%
Duty=5%
Duty=10%
Duty=20%
Duty=50%
DC
0
-30
-10
10
30
50
70
90
-30
-10
10
30
50
70
90
Ambient Temperature : Ta(℃)
Ambient Temperature : Ta(℃)
Ambient Temperature vs. Forward Voltage
Pulse Forward Voltage vs. Pulse Forward Current
Condition : IF = 20mA
Condition : Ta=25℃, tw≦100μs, Duty≦1/100
1.8
1000
100
10
1.6
1.4
1.2
1.0
1
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
-40
-20
0
20
40
60
80
100
Ambient Temperature : Ta (℃)
Pulse Forward Voltage : VFM(V)
Page 6