欢迎访问ic37.com |
会员登录 免费注册
发布采购

SST36VF3204-70-4E-B3KE 参数 Datasheet PDF下载

SST36VF3204-70-4E-B3KE图片预览
型号: SST36VF3204-70-4E-B3KE
PDF下载: 下载PDF文件 查看货源
内容描述: 32兆位( X8 / X16 )并行的SuperFlash [32 Mbit (x8/x16) Concurrent SuperFlash]
分类和应用: 内存集成电路
文件页数/大小: 34 页 / 432 K
品牌: SST [ SILICON STORAGE TECHNOLOGY, INC ]
 浏览型号SST36VF3204-70-4E-B3KE的Datasheet PDF文件第2页浏览型号SST36VF3204-70-4E-B3KE的Datasheet PDF文件第3页浏览型号SST36VF3204-70-4E-B3KE的Datasheet PDF文件第4页浏览型号SST36VF3204-70-4E-B3KE的Datasheet PDF文件第5页浏览型号SST36VF3204-70-4E-B3KE的Datasheet PDF文件第7页浏览型号SST36VF3204-70-4E-B3KE的Datasheet PDF文件第8页浏览型号SST36VF3204-70-4E-B3KE的Datasheet PDF文件第9页浏览型号SST36VF3204-70-4E-B3KE的Datasheet PDF文件第10页  
32 Mbit Concurrent SuperFlash  
SST36VF3203 / SST36VF3204  
Data Sheet  
address from the same bank without issuing a new Soft-  
ware ID Entry command. The Software ID Entry command  
may be written to an address within a bank that is in Read  
Mode or in Erase-Suspend mode. The Software ID Entry  
command may not be written while the device is program-  
ming or erasing in the other bank.  
Security ID  
The SST36VF320x devices offer a 136-word Security ID  
space. The Secure ID space is divided into two seg-  
ments—one 128-bit factory programmed segment and one  
128-word (256-byte) user-programmed segment. The first  
segment is programmed and locked at SST with a unique,  
128-bit number. The user segment is left un-programmed  
for the customer to program as desired. To program the  
user segment of the Security ID, the user must use the  
Security ID Program command. End-of-Write status is  
checked by reading the toggle bits. Data# Polling is not  
used for Security ID End-of-Write detection. Once pro-  
gramming is complete, the Sec ID should be locked using  
the User Sec ID Program Lock-Out. This disables any  
future corruption of this space. Note that regardless of  
whether or not the Sec ID is locked, neither Sec ID seg-  
ment can be erased. The Secure ID space can be queried  
by executing a three-byte command sequence with Query  
Sec ID command (88H) at address 555H in the last byte  
sequence. See Figure 14 for timing diagram. To exit this  
mode, the Exit Sec ID command should be executed.  
Refer to Table 7 for more details.  
TABLE 2: PRODUCT IDENTIFICATION  
Address  
Data  
Manufacturer’s ID  
Device ID  
BKX0000H 00BFH  
SST36VF3203  
SST36VF3204  
BKX0001H 7354H  
BKX0001H 7353H  
T2.1 1270  
Note: BKX = Bank Address (A20-A18  
)
Product Identification Mode  
Exit/CFI Mode Exit  
In order to return to the standard Read mode, the Software  
Product Identification mode must be exited. Exit is accom-  
plished by issuing the Software ID Exit command  
sequence, which returns the device to the Read mode. This  
command may also be used to reset the device to the Read  
mode after any inadvertent transient condition that appar-  
ently causes the device to behave abnormally, e.g., not read  
correctly. Please note that the Software ID Exit/CFI Exit  
command is ignored during an internal Program or Erase  
operation. See Table 7 for the software command code, Fig-  
ure 13 for timing waveform and Figure 21 for a flowchart.  
Product Identification  
The Product Identification mode identifies the devices and  
manufacturer. For details, see Table 2 for software opera-  
tion, Figure 11 for the Software ID Entry and Read timing  
diagram and Figure 21 for the Software ID Entry command  
sequence flowchart. The addresses A20 and A18 indicate a  
bank address. When the addressed bank is switched to  
Product Identification mode, it is possible to read another  
FUNCTIONAL BLOCK DIAGRAM  
(8 KWord / 16 KByte  
Sector Protection)  
Address  
Buffers  
Memory  
Address  
SuperFlash Memory  
Bank 1  
BYTE#  
RST#  
CE#  
SuperFlash Memory  
Bank 2  
Control  
Logic  
WP#  
DQ /A - DQ  
15 -1  
I/O Buffers  
WE#  
0
OE#  
1270 B01.0  
RY/BY#  
©2005 Silicon Storage Technology, Inc.  
S71270-03-000  
7/06  
6
 复制成功!