16 Mbit Concurrent SuperFlash
SST36VF1601E / SST36VF1602E
Data Sheet
TABLE 5: SOFTWARE COMMAND SEQUENCE
Command
Sequence
1st Bus
Write Cycle
2nd Bus
Write Cycle
3rd Bus
Write Cycle
4th Bus
Write Cycle
5th Bus
Write Cycle
6th Bus
Write Cycle
Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2
555H
555H
AAH
AAH
AAH
AAH
B0H
30H
AAH
AAH
2AAH
2AAH
2AAH
2AAH
55H
55H
55H
55H
555H
555H
555H
555H
A0H
80H
80H
80H
WA3
555H
555H
555H
Data
AAH
AAH
AAH
Program
4
4
2AAH
2AAH
2AAH
55H
55H
55H
SAX
BAX
30H
50H
10H
Sector-Erase
Block-Erase
Chip-Erase
555H
555H
555H
XXXXH
XXXXH
555H
Erase-Suspend
Erase-Resume
Query Sec ID5
2AAH
2AAH
55H
55H
555H
555H
88H
A5H
555H
SIWA6
XXH
Data
User Security ID
Program
555H
AAH
2AAH
55H
555H
85H
0000H
User Security ID
Program Lock-out7
9
Software ID Entry8
CFI Query Entry
555H
555H
555H
AAH
AAH
AAH
2AAH
2AAH
2AAH
55H
55H
55H
BKX
90H
98H
F0H
555H
9
BKX
555H
555H
Software ID Exit/
CFI Exit/
Sec ID Exit10,11
XXH
F0H
Software ID Exit/
CFI Exit/
Sec ID Exit10,11
T5.1 1274
1. Address format A10-A0 (Hex), Addresses A19-A11 can be VIL or VIH, but no other value, for the command sequence when in x16 mode.
When in x8 mode, Addresses A19-A12, Address A-1 and DQ14-DQ8 can be VIL or VIH, but no other value, for the command sequence.
2. DQ15-DQ8 can be VIL or VIH, but no other value, for the command sequence
3. WA = Program word/byte address
4. SAX for Sector-Erase; uses A19-A11 address lines
BAX for Block-Erase; uses A19-A15 address lines
5. For SST36VF1601E,
SST ID is read with A3 = 0 (Address range = 00000H to 00007H),
User ID is read with A3 = 1 (Address range = 00010H to 00017H).
Lock Status is read with A7-A0 = 000FFH. Unlocked: DQ3 = 1 / Locked: DQ3 = 0.
For SST36VF1602E,
SST ID is read with A3 = 0 (Address range = C0000H to C0007H),
User ID is read with A3 = 1 (Address range = C0010H to C0017H).
Lock Status is read with A7-A0 = C00FFH. Unlocked: DQ3 = 1 / Locked: DQ3 = 0.
6. SIWA = User Security ID Program word/byte address
For SST36VF1601E, valid Word-Addresses for User Sec ID are from 00010H-00017H.
For SST36VF1602E, valid Word-Addresses for User Sec ID are from C0010H-C0017H.
All 4 cycles of User Security ID Program and Program Lock-out must be completed before going back to Read-Array mode.
7. The User Security ID Program Lock-out command must be executed in x16 mode (BYTE#=VIH).
8. The device does not remain in Software Product Identification mode if powered down.
9. A19 and A18 = BKX (Bank Address): address of the bank that is switched to Software ID/CFI Mode
With A17-A1 = 0;SST Manufacturer’s ID = 00BFH, is read with A0 = 0
SST36VF1601E Device ID = 734BH, is read with A0 = 1
SST36VF1602E Device ID = 734AH, is read with A0 = 1
10. Both Software ID Exit operations are equivalent
11. If users never lock after programming, User Sec ID can be programmed over the previously unprogrammed bits (data=1) using the
User Sec ID mode again (the programmed “0” bits cannot be reversed to “1”).
For SST36VF1601E, valid Word-Addresses for User Sec ID are from 00010H-00017H.
For SST36VF1602E, valid Word-Addresses for User Sec ID are from C0010H-C0017H.
©2005 Silicon Storage Technology, Inc.
S71274-03-000
11/05
13