 浏览型号SST25VF080B-80-4I-PAE的Datasheet PDF文件第4页浏览型号SST25VF080B-80-4I-PAE的Datasheet PDF文件第5页浏览型号SST25VF080B-80-4I-PAE的Datasheet PDF文件第6页浏览型号SST25VF080B-80-4I-PAE的Datasheet PDF文件第7页浏览型号SST25VF080B-80-4I-PAE的Datasheet PDF文件第9页浏览型号SST25VF080B-80-4I-PAE的Datasheet PDF文件第10页浏览型号SST25VF080B-80-4I-PAE的Datasheet PDF文件第11页浏览型号SST25VF080B-80-4I-PAE的Datasheet PDF文件第12页  
8 Mbit SPI Serial Flash  
SST25VF080B  
Data Sheet  
Instructions  
Instructions are used to read, write (Erase and Program),  
and configure the SST25VF080B. The instruction bus  
cycles are 8 bits each for commands (Op Code), data, and  
addresses. Prior to executing any Byte-Program, Auto  
Address Increment (AAI) programming, Sector-Erase,  
Block-Erase, Write-Status-Register, or Chip-Erase instruc-  
tions, the Write-Enable (WREN) instruction must be exe-  
cuted first. The complete list of instructions is provided in  
Table 5. All instructions are synchronized off a high to low  
transition of CE#. Inputs will be accepted on the rising edge  
of SCK starting with the most significant bit. CE# must be  
driven low before an instruction is entered and must be  
driven high after the last bit of the instruction has been  
shifted in (except for Read, Read-ID, and Read-Status-  
Register instructions). Any low to high transition on CE#,  
before receiving the last bit of an instruction bus cycle, will  
terminate the instruction in progress and return the device  
to standby mode. Instruction commands (Op Code),  
addresses, and data are all input from the most significant  
bit (MSB) first.  
TABLE 5: Device Operation Instructions  
Address  
Cycle(s)2  
Dummy  
Cycle(s)  
Data  
Cycle(s)  
Instruction  
Description  
Op Code Cycle1  
0000 0011b (03H)  
0000 1011b (0BH)  
0010 0000b (20H)  
Read  
Read Memory  
3
3
3
0
1
0
1 to  
1 to ∞  
0
High-Speed Read  
4 KByte Sector-Erase3  
Read Memory at higher speed  
Erase 4 KByte of  
memory array  
32 KByte Block-Erase4  
64 KByte Block-Erase5  
Chip-Erase  
Erase 32 KByte block  
of memory array  
0101 0010b (52H)  
1101 1000b (D8H)  
3
3
0
0
0
0
0
0
0
Erase 64 KByte block  
of memory array  
Erase Full Memory Array  
0110 0000b (60H) or  
1100 0111b (C7H)  
Byte-Program  
AAI-Word-Program6  
To Program One Data Byte  
0000 0010b (02H)  
1010 1101b (ADH)  
3
3
0
0
1
Auto Address Increment  
Programming  
2 to ∞  
RDSR7  
EWSR  
WRSR  
WREN  
WRDI  
Read-Status-Register  
Enable-Write-Status-Register  
Write-Status-Register  
Write-Enable  
0000 0101b (05H)  
0101b 0000b (50H)  
0000 0001b (01H)  
0000 0110b (06H)  
0000 0100b (04H)  
0
0
0
0
0
3
0
0
0
0
0
0
1 to ∞  
0
1
0
Write-Disable  
0
RDID8  
Read-ID  
1001 0000b (90H) or  
1010 1011b (ABH)  
1 to ∞  
JEDEC-ID  
EBSY  
JEDEC ID read  
1001 1111b (9FH)  
0111 0000b (70H)  
0
0
0
0
3 to ∞  
Enable SO to output RY/BY#  
status during AAI programming  
0
DBSY  
Disable SO to output RY/BY#  
status during AAI programming  
1000 0000b (80H)  
0
0
0
T5.0 1296  
1. One bus cycle is eight clock periods.  
2. Address bits above the most significant bit of each density can be VIL or VIH.  
3. 4KByte Sector Erase addresses: use AMS-A12, remaining addresses are don’t care but must be set either at VIL or VIH.  
4. 32KByte Block Erase addresses: use AMS-A15, remaining addresses are don’t care but must be set either at VIL or VIH.  
5. 64KByte Block Erase addresses: use AMS-A16, remaining addresses are don’t care but must be set either at VIL or VIH.  
6. To continue programming to the next sequential address location, enter the 8-bit command, ADH, followed by 2 bytes of data to be  
programmed. Data Byte 0 will be programmed into the initial address [A23-A1] with A0=0, Data Byte 1 will be programmed into the  
initial address [A23-A1] with A0=1.  
7. The Read-Status-Register is continuous with ongoing clock cycles until terminated by a low to high transition on CE#.  
8. Manufacturer’s ID is read with A0=0, and Device ID is read with A0=1. All other address bits are 00H. The Manufacturer’s ID and  
device ID output stream is continuous until terminated by a low-to-high transition on CE#.  
©2010 Silicon Storage Technology, Inc.  
S71296-04-000  
01/10  
8