M25PE10, M25PE20
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the devices. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 9. Operating Conditions
Symbol
Parameter
Min.
2.7
Max.
3.6
Unit
V
V
Supply Voltage
Ambient Operating Temperature
CC
TA
–40
85
°C
Table 10. AC Measurement Conditions
Symbol
Parameter
Min.
Max.
Unit
pF
ns
V
C
Load Capacitance
30
L
Input Rise and Fall Times
5
0.2V to 0.8V
Input Pulse Voltages
CC
CC
CC
0.3V to 0.7V
Input and Output Timing Reference Voltages
V
CC
Note: Output Hi-Z is defined as the point where data out is no longer driven.
Figure 21. AC Measurement I/O Waveform
Input Levels
Input and Output
Timing Reference Levels
0.8V
CC
CC
0.7V
CC
0.3V
CC
0.2V
AI00825B
Table 11. Capacitance
Symbol
COUT
Parameter
Test Condition
= 0V
Min.
Max.
Unit
pF
Output Capacitance (Q)
V
8
6
OUT
CIN
Input Capacitance (other pins)
V
= 0V
pF
IN
Note: Sampled only, not 100% tested, at T =25°C and a frequency of 20 MHz.
A
26/37