S110-X  
1 Form A  
Solid State Relay  
PERFORMANCE DATA  
S110-X  
Maximum Load Current vs. Temperature  
S110-X  
Typical Blocking Voltage Distribution  
N = 100, Ambient Temperature = 25°C  
40  
30  
20  
10  
0
1000  
800  
600  
400  
200  
0
425 450 475 500 525 550 575 600  
Blocking Voltage (V)  
0
0
0
4
20  
40  
60  
80  
-
-2  
Temperature (C)  
ZERO-VOLT SWITCHING  
This solid state relay has been designed with a driver circuit that controls the operation of two back-to-back silicon controlled rectifiers  
(SCRs), each responsible for one half of the AC cycle. If an AC signal is examined, the turn on, turn off and zero-volt switching can be seen.  
Figure 1 shows a typical 60 Hz, 120Vac signal with a corresponding relay input signal:  
5
Relay Input Signal is  
Turned On.  
Relay Input Signal is  
Turned Off.  
1
Input Signal  
SCR #1 Turns On when  
5V threshold is reached.  
2
6
SCR #1 and Relay Turn  
Off at Zero Volts.  
5 V  
Threshold  
3
4
SCR #1 Turns Off,  
SCR #2 Turns On  
at Zero Volts.  
SCR #2 Turns Off,  
SCR #1 Turns On  
at Zero Volts.  
Figure 1 shows the sequence of zero-volt switching operation. At Stage 1, an input signal is applied to the relay. The relay will not turn on  
until the threshold voltage of 5V is reached. Once this point is reached (Stage 2), SCR #1 (designated as the SCR which controls positive  
AC voltage) turns on. However, SCR #1 only conducts for an instant, as the cycle quickly crosses zero. At this point (Stage 3), SCR #1 will  
turn off and SCR #2 (negative AC voltage) turns on. Likewise, at the next zero cross (Stage 4), SCR #2 will turn off and SCR #1 conducts  
again. Even though the input signal is terminated at Stage 5, the relay will continue to conduct (typical SCR behavior) until Stage 6, when  
SCR #1 crosses zero and ceases to conduct. Please note that turn on can likewise begin on the negative phase of the AC cycle with a -5V  
threshold, though only the positive phase is shown here.  
© 2004 Solid State Optronics • San José, CA  
www.ssousa.com • +1.408.293.4600  
Page 3 of 5  
S110-X  
rev 1.40 (10/25/2004)