欢迎访问ic37.com |
会员登录 免费注册
发布采购

SL23EP09SI-1 参数 Datasheet PDF下载

SL23EP09SI-1图片预览
型号: SL23EP09SI-1
PDF下载: 下载PDF文件 查看货源
内容描述: 低抖动和偏斜10到220MHz的零延迟缓冲器( ZDB ) [Low Jitter and Skew 10 to 220MHz Zero Delay Buffer (ZDB)]
分类和应用:
文件页数/大小: 13 页 / 157 K
品牌: SPECTRALINEAR [ SPECTRALINEAR INC ]
 浏览型号SL23EP09SI-1的Datasheet PDF文件第3页浏览型号SL23EP09SI-1的Datasheet PDF文件第4页浏览型号SL23EP09SI-1的Datasheet PDF文件第5页浏览型号SL23EP09SI-1的Datasheet PDF文件第6页浏览型号SL23EP09SI-1的Datasheet PDF文件第8页浏览型号SL23EP09SI-1的Datasheet PDF文件第9页浏览型号SL23EP09SI-1的Datasheet PDF文件第10页浏览型号SL23EP09SI-1的Datasheet PDF文件第11页  
SL23EP09  
AC Electrical Specifications (VDD=3.3V and 2.5V)  
Symbol  
Description  
Condition  
Min  
10  
10  
10  
10  
25  
40  
47  
45  
Typ  
Max  
220  
167  
200  
133  
75  
Unit  
MHz  
MHz  
MHz  
MHz  
%
FMAX  
Maximum Frequency [1]  
(Input=Output )  
3.3V High Drive  
3.3V Standard Drive  
2.5V High Drive  
2.5V Standard Drive  
INDC  
Input Duty Cycle  
<135 MHz, VDD=3.3V  
<135 MHz, VDD=2.5V  
60  
%
OUTDC Output Duty Cycle[2]  
<135 MHz, VDD=3.3V  
53  
%
<135 MHz, VDD=2.5V  
55  
%
tr/f3.3  
Rise, Fall Time (3.3V) [2]  
(Measured at: 0.8 to 2.0V)  
Std drive, CL = 30 pF, <100 MHz  
Std drive, CL = 22 pF, <135 MHz  
Std drive, CL = 15 pF, <170 MHz  
High drive, CL = 30 pF, <100 MHz  
High drive, CL = 22 pF, <135 MHz  
High drive, CL = 15 pF, >135 MHz  
Std drive, CL = 15 pF, <135 MHz  
High drive, CL = 30 pF, <100 MHz  
High drive, CL = 22 pF, <135 MHz  
High drive, CL = 15 pF, >135 MHz  
1.6  
1.6  
0.6  
1.2  
1.2  
0.5  
1.5  
2.1  
1.3  
1.2  
ns  
ns  
ns  
ns  
ns  
ns  
tr/f2.5  
Rise, Fall Time (2.5) [2]  
ns  
(Measured at: 0.6 to 1.8V)  
ns  
ns  
ns  
t1  
t2  
t3  
Output-to-Output Skew [9]  
(Measured at VDD/2)  
All outputs CL=0, 3.3V supply, 2.5 power  
supply, standard drive  
45  
100  
110  
ps  
ps  
All outputs CL=0, 2.5V power supply, high  
drive  
Delay Time, CLKIN Rising  
Edge to CLKOUT Rising  
Edge[2]  
PLL Bypass mode  
PLL enabled @ 3.3V  
PLL enabled @2.5V  
1.5  
4.4  
100  
200  
ns  
ps  
ps  
–100  
–200  
(Measured at VDD/2)  
Part-to-Part Skew[2]  
(Measured at VDD/2)  
Measured at VDD/2. Any output to any  
output, 3.3V supply  
150  
300  
ps  
ps  
Measured at VDD/2. Any output to any  
output, 2.5V supply  
Notes:  
1. For the given maximum loading conditions. See CL in Operating Conditions Table.  
2. Parameter is guaranteed by design and characterization. Not 100% tested in production.  
Rev 1.1, February 2, 2007  
Page 7 of 13