ABSOLUTE MAXIMUM RATINGS
OPERATING RANGES
Storage Temperature . . . . . . . . . . . . –65°C to +150°C
Plastic Packages . . . . . . . . . . . . . . . –65°C to +125°C
Commercial (C) Devices
Ambient Temperature (TA) . . . . . . . . . . .0°C to +70°C
Industrial (I) Devices
Ambient Temperature
with Power Applied. . . . . . . . . . . . . .–55°C to + 125°C
Ambient Temperature (TA) . . . . . . . . .–40°C to +85°C
Extended (E) Devices
Voltage with Respect To Ground
All pins except A9 and VPP
(Note 1) . . . . . . . . . . . . . . . . . . . . . . .–2.0 V to +7.0 V
Ambient Temperature (TA) . . . . . . . .–55°C to +125°C
V
CC (Note 1). . . . . . . . . . . . . . . . . . . .–2.0 V to +7.0 V
VCC Supply Voltages
A9 (Note 2). . . . . . . . . . . . . . . . . . . .–2.0 V to +14.0 V
VPP (Note 2). . . . . . . . . . . . . . . . . . .–2.0 V to +14.0 V
Output Short Circuit Current (Note 3) . . . . . . 200 mA
VCC . . . . . . . . . . . . . . . . . . . . . . . . +4.50 V to +5.50 V
VPP Voltages
Read . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to +12.6 V
Program, Erase, and Verify. . . . . . +11.4 V to +12.6 V
Notes:
1. Minimum DC voltage on input or I/O pins is –0.5 V. During
Operating ranges define those limits between which the
functionality of the device is guaranteed.
voltage transitions, inputs may overshoot V to –2.0 V for
SS
periods of up to 20 ns. Maximum DC voltage on input and
I/O pins is V + 0.5 V. During voltage transitions, input
CC
and I/O pins may overshoot to V + 2.0 V for periods up
CC
to 20ns.
2. Minimum DC input voltage on A9 and V pins is –0.5 V.
PP
During voltage transitions, A9 and V may overshoot
PP
V
to –2.0 V for periods of up to 20 ns. Maximum DC
SS
input voltage on A9 and V is +13.0 V which may
PP
overshoot to 14.0 V for periods up to 20 ns.
3. No more than one output shorted to ground at a time.
Duration of the short circuit should not be greater than
one second.
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device. This is
a stress rating only; functional operation of the device at
these or any other conditions above those indicated in the op-
erational sections of this specification is not implied. Expo-
sure of the device to absolute maximum rating conditions for
extended periods may affect device reliability.
Am28F256A