CXA3106Q
C) Description of readout mode
This program has a function (readout mode) that reads the contents written to the control registers from the
CXA3106Q SEROUT (Pin 15) and displays these contents on the screen. This function is described below.
1) Set SCAN to ON at the function setting screen.
2) Press the S key.
The following screen appears.
SCAN RESULT, CXA3106 PLL REGISTERS
Register 1 DIVREG1
Register 2 DIVREG2
Register 3 CENFREREG
Register 4 DELAYREG
Register 5 CPREG
00111000
0101
1011111
0010000
100
Register 6 TTLPOLREG
00000011
Register 7 TESTPOWREG 0111
Press r to return to PLL REGISTERS MENU.
Press a to abort
MIXED SIGNAL SYSTEMS AUG 1996
This screen conforms to the Control Register Table listed in the CXA3106Q specifications.
3) Press the R key to return to the original function setting screen.
D) Quit the program
Press the A key to quit the program.
– 46 –