欢迎访问ic37.com |
会员登录 免费注册
发布采购

CXA3106Q 参数 Datasheet PDF下载

CXA3106Q图片预览
型号: CXA3106Q
PDF下载: 下载PDF文件 查看货源
内容描述: PLL IC为液晶显示器/投影仪 [PLL IC for LCD Monitor/Projector]
分类和应用: 显示器
文件页数/大小: 50 页 / 957 K
品牌: SONY [ SONY CORPORATION ]
 浏览型号CXA3106Q的Datasheet PDF文件第40页浏览型号CXA3106Q的Datasheet PDF文件第41页浏览型号CXA3106Q的Datasheet PDF文件第42页浏览型号CXA3106Q的Datasheet PDF文件第43页浏览型号CXA3106Q的Datasheet PDF文件第45页浏览型号CXA3106Q的Datasheet PDF文件第46页浏览型号CXA3106Q的Datasheet PDF文件第47页浏览型号CXA3106Q的Datasheet PDF文件第48页  
CXA3106Q  
Divisor  
This is used to input the frequency division ratio of the program counter. The value can be changed as  
desired from 9 to 4111 by moving the cursor to the position of the number and pressing the Return or Enter  
key. (Note: The operating range of the CXA3106Q is from 256 to 4096.) The value can also be incremented  
or decremented by one step by pressing the Page Up or Page Down key, respectively.  
The internal VCO has an oscillator frequency of 40 to 120MHz, so the output frequency and Divider (VCO  
frequency divider) setting range are as follows.  
40  
Divider = 1  
120  
1/1  
1/2  
20 Divider = 2 60  
10  
30  
1/4  
Divider = 4  
40  
80  
120  
O/P Frequency [MHz]  
Divider  
This sets the VCO output frequency division ratio to 1/1, 1/2 or 1/4. The frequency division ratio changes  
repeatedly in the order of 1/1 1/2 1/4 1/1 each time the cursor is moved to the position of the number  
and the Return or Enter key is pressed.  
Coarse Delay  
This is the DSYNC upper delay time setting. The value can be changed by moving the cursor to the position  
of the number and pressing the Return or Enter key. The delay time variable range settings are "00" (1 CLK),  
"01" (2 CLK), "10" (3 CLK) or "11" (4 CLK).  
Fine Delay  
This is the DSYNC lower delay time setting. The value can be changed by moving the cursor to the position  
of the number and pressing the Return or Enter key. The value can also be incremented or decremented by  
one step by pressing the Page Up or Page Down key, respectively. The delay time can be varied from 1/16  
CLK to 32/16 CLK by setting "0" to "31", respectively.  
Charge Pump  
This is the charge pump circuit KI setting. The value can be changed by moving the cursor to the position of  
the number and pressing the Return or Enter key. KI can be set to "00" (about 100µA), "10" (about 400µA) or  
"11" (about 1.6mA).  
The setting "01" is not used. (Setting "01" is the same as setting "00".)  
Polarity  
These are the SYNC, DSYNC and PD (Phase Detector) polarity inversion settings, and should be set as  
necessary such as when inverting the SYNC input and DSYNC output waveforms. The setting value "1" is  
positive polarity, and "0" is negative polarity. These should normally all be set to "1". (Fix PD to "1" other than  
during test mode.)  
– 44 –  
 复制成功!