CXA2016S
Electrical Characteristics
(Ta=25 °C, VCC=5 V. See the Electrical Characteristics Measurement Circuit.)
Measurement
No.
Item
Symbol
Measurement contents
Min. Typ. Max. Unit
High level
point
Measure VD output peak value
during V. separate sync input.
Input signal A. (tw=60 µs)
VD output
voltage
VD
4.3
4.9
Low level
0.1
—
0.4
—
1
EVD
V
V
V
V
(Pin 21)
—
Measure HD output peak value
during sync on video input.
Input signal C. (tw=1 µs)
High level
4.2
HD output
voltage
HD
3.3
—
2
3
EHD
(Pin 18)
Low level
0.3
0.5
—
CLAMP
(Pin 13)
High level
4.9
4.3
—
Measure clamp pulse output peak
value during composite sync input.
Input signal B. (tw=1 µs)
Low level
0.3
Clamp pulse
0.8
—
ECP
output voltage
CLAMP
(Pin 14)
High level
4.9
4.3
Low level
0.4
—
0.9
Measure clamp pulse output pulse
width during composite sync input.
Input signal B. (tw=1 µs)
CLAMP
(Pin 13)
CLAMP
(Pin 14)
Clamp pulse
output pulse
width
260
305
310
380
ns
ns
4
5
tC
260
—
380
100
Measure delay difference between
CS and HD during composite sync
input. Or the time from CS
(positive polarity) rise time (50 %)
to HD output rise time (50 %).
Input signal D.
HD
HD delay
thd
75
ns
(Pin 18)
Measure delay difference between
HD and clamp pulse during
composite sync input. Or the time
from HD output fall time (50 %) to
clamp pulse output rise time 1 (50
%). Input signal B.
CLAMP
(Pin 13)
—
—
5.0
5.0
30
30
Clamp pulse
delay
6
tcd1
ns
V
CLAMP
(Pin 14)
Sync signal polarity information
is output.
PH, PV
(Pins 16
and 17)
PN
4.3
—
—
Measure high level voltage.
(No load)
Polarity
7
8
identification
output voltage
Sync signal polarity information
is output.
PH, PV
(Pins 16
and 17)
PP
—
—
—
0.4
45
V
Measure low level voltage.
(No load)
Current
VCC=5 V. Measure current
consumption during no signal input.
VCC
ICC
26.5
mA
consumption
(Pin 22)
1 CLAMP is for the fall time.
—6—