CXA2016S  
Electrical Characteristics  
(Ta=25 °C, VCC=5 V. See the Electrical Characteristics Measurement Circuit.)  
Measurement  
No.  
Item  
Symbol  
Measurement contents  
Min. Typ. Max. Unit  
High level  
point  
Measure VD output peak value  
during V. separate sync input.  
Input signal A. (tw=60 µs)  
VD output  
voltage  
VD  
4.3  
4.9  
Low level  
0.1  
0.4  
1
EVD  
V
V
V
V
(Pin 21)  
Measure HD output peak value  
during sync on video input.  
Input signal C. (tw=1 µs)  
High level  
4.2  
HD output  
voltage  
HD  
3.3  
2
3
EHD  
(Pin 18)  
Low level  
0.3  
0.5  
CLAMP  
(Pin 13)  
High level  
4.9  
4.3  
Measure clamp pulse output peak  
value during composite sync input.  
Input signal B. (tw=1 µs)  
Low level  
0.3  
Clamp pulse  
0.8  
ECP  
output voltage  
CLAMP  
(Pin 14)  
High level  
4.9  
4.3  
Low level  
0.4  
0.9  
Measure clamp pulse output pulse  
width during composite sync input.  
Input signal B. (tw=1 µs)  
CLAMP  
(Pin 13)  
CLAMP  
(Pin 14)  
Clamp pulse  
output pulse  
width  
260  
305  
310  
380  
ns  
ns  
4
5
tC  
260  
380  
100  
Measure delay difference between  
CS and HD during composite sync  
input. Or the time from CS  
(positive polarity) rise time (50 %)  
to HD output rise time (50 %).  
Input signal D.  
HD  
HD delay  
thd  
75  
ns  
(Pin 18)  
Measure delay difference between  
HD and clamp pulse during  
composite sync input. Or the time  
from HD output fall time (50 %) to  
clamp pulse output rise time 1 (50  
%). Input signal B.  
CLAMP  
(Pin 13)  
5.0  
5.0  
30  
30  
Clamp pulse  
delay  
6
tcd1  
ns  
V
CLAMP  
(Pin 14)  
Sync signal polarity information  
is output.  
PH, PV  
(Pins 16  
and 17)  
PN  
4.3  
Measure high level voltage.  
(No load)  
Polarity  
7
8
identification  
output voltage  
Sync signal polarity information  
is output.  
PH, PV  
(Pins 16  
and 17)  
PP  
0.4  
45  
V
Measure low level voltage.  
(No load)  
Current  
VCC=5 V. Measure current  
consumption during no signal input.  
VCC  
ICC  
26.5  
mA  
consumption  
(Pin 22)  