CXA1695L
See Electrical Characteristics Test Circuit (Ta=25°C, VCC=9V)
Electrical Characteristics
Item
Symbol
Measurement conditions
Min. Typ. Max. Unit
Circuit current
IccV
IccU
CG1
CG2
CG3
CG4
NF1
NF2
NF3
NF4
CM1
VHF operation, no signal
45.0 58.0
45.0 58.0
mA
mA
dB
dB
dB
dB
dB
dB
dB
dB
dBµ
UHF operation, no signal
Conversion gain
1
VHF operation, fRF=55 MHz, input level –40 dBm
17.5 20.5 23.5
VHF operation, fRF=360 MHz, input level –40 dBm 18.0 21.0 24.0
UHF operation, fRF=360 MHz, input level –40 dBm 23.0 26.0 29.0
UHF operation, fRF=800 MHz, input level –40 dBm 24.0 27.0 30.0
Noise figure
1 2
VHF operation, fRF=55 MHz
VHF operation, fRF=360 MHz
UHF operation, fRF=360 MHz
UHF operation, fRF=800 MHz
VHF operation, fD=55 MHz
fUD=±12 MHz
9.5
12.5
10.0 13.0
6.0
7.0
10.0
11.0
1% cross
modulation
1 3
95.0 99.0
CM2
CM3
CM4
VHF operation, fD=360 MHz
fUD=±12 MHz
93.0 97.0
86.0 90.0
86.0 90.0
+8.0 +12.0
dBµ
dBµ
dBµ
dBm
UHF operation, fD=360 MHz
fUD=±12 MHz
UHF operation, fD=800 MHz
fUD=±12 MHz
Max. output
power
Pomax 50Ωload
(sat)
∆fsw1 VHF operation, fosc=100 MHz
Frequency drift from 3 s to 3 min. after switch ON
∆fsw2 VHF operation, fosc=405 MHz
Frequency drift from 3 s to 3 min. after switch ON
∆fsw2 UHF operation, fosc=405 MHz
Frequency drift from 3 s to 3 min. after switch ON
∆fsw4 UHF operation, fosc=845 MHz
Frequency drift from 3 s to 3 min. after switch ON
∆fst1 VHF operation, fosc=100 MHz
Frequency shift when VCC +9 V changes ±5 %
∆fst2 VHF operation, fosc=405 MHz
Frequency shift when VCC +9 V changes ±5 %
∆fst3 UHF operation, fosc=405 MHz
Frequency shift when VCC +9 V changes ±5 %
∆fst4 UHF operation, fosc=845 MHz
Frequency shift when Vcc +9 V changes ±5 %
±300 kHz
±400 kHz
±600 kHz
±700 kHz
±200 kHz
±300 kHz
±400 kHz
±400 kHz
Switch ON drift
+B supply
voltage drift
1) Measured value for untuned inputs. Unbalanced input for VHF; balanced input for UHF.
2) Noise figure is uncorrected for image.
3) Desired signal (fD) input level is –34 dBm. Undesired signal (fUD) is 100 kHz at 40 %AM. The
measurement value is undesired signal level, it measured with spectrum analyzer at S/I=46 dB.
—4—