SN8P2604A
8-Bit Micro-Controller
)
MULTI-ADDRESS JUMPING
Users can jump around the multi-address by either JMP instruction or ADD M, A instruction (M = PCL) to activate
multi-address jumping function. Program Counter supports “ADD M,A”, ”ADC M,A” and “B0ADD M,A” instructions
for carry to PCH when PCL overflow automatically. For jump table or others applications, users can calculate PC value
by the three instructions and don’t care PCL overflow problem.
Note: PCH only support PC up counting result and doesn’t support PC down counting. When PCL is
carry after PCL+ACC, PCH adds one automatically. If PCL borrow after PCL–ACC, PCH keeps value and
not change.
¾
Example: If PC = 0323H (PCH = 03H, PCL = 23H)
; PC = 0323H
MOV
B0MOV
…
A, #28H
PCL, A
; Jump to address 0328H
; Jump to address 0300H
; PC = 0328H
MOV
B0MOV
…
A, #00H
PCL, A
¾
Example: If PC = 0323H (PCH = 03H, PCL = 23H)
; PC = 0323H
B0ADD
JMP
JMP
JMP
JMP
…
PCL, A
; PCL = PCL + ACC, the PCH cannot be changed.
; If ACC = 0, jump to A0POINT
; ACC = 1, jump to A1POINT
; ACC = 2, jump to A2POINT
; ACC = 3, jump to A3POINT
A0POINT
A1POINT
A2POINT
A3POINT
…
SONiX TECHNOLOGY CO., LTD
Page 30
Version 0.3