SN8P2740 Series  
ADC, OP-amp, Comparator 8-Bit Micro-Controller  
The LVD (low voltage detector) is built-in Sonix 8-bit MCU to be brown out reset protection. When the VDD drops and  
is below LVD detect voltage, the LVD would be triggered, and the system is reset. The LVD detect level is different by  
each MCU. The LVD voltage level is a point of voltage and not easy to cover all dead-band range. Using LVD to  
improve brown out reset is depend on application requirement and environment. If the power variation is very deep,  
violent and trigger the LVD, the LVD can be the protection. If the power variation can touch the LVD detect level and  
make system work error, the LVD cant be the protection and need to other reset methods. More detail LVD information  
is in the electrical characteristic section.  
The LVD is three levels design (2.0V/2.4V/3.6V) and controlled by LVD code option. The 2.0V LVD is always enable for  
power on reset and Brown Out reset. The 2.4V LVD includes LVD reset function and flag function to indicate VDD  
status function. The 3.6V includes flag function to indicate VDD status. LVD flag function can be an easy low battery  
detector. LVD24, LVD36 flags indicate VDD voltage level. For low battery detect application, only checking LVD24,  
LVD36 status to be battery status. This is a cheap and easy solution.  
086H  
PFLAG  
Read/Write  
After reset  
Bit 7  
NT0  
R/W  
-
Bit 6  
NPD  
R/W  
-
Bit 5  
LVD36  
R
Bit 4  
LVD24  
R
Bit 3  
Bit 2  
C
R/W  
0
Bit 1  
DC  
R/W  
0
Bit 0  
Z
R/W  
0
-
-
-
0
0
Bit 5  
Bit 4  
LVD36: LVD 3.6V operating flag and only support LVD code option is LVD_H.  
0 = Inactive (VDD > 3.6V).  
1 = Active (VDD 3.6V).  
LVD24: LVD 2.4V operating flag and only support LVD code option is LVD_M.  
0 = Inactive (VDD > 2.4V).  
1 = Active (VDD 2.4V).  
LVD Code Option  
LVD  
LVD_L  
LVD_M  
LVD_H  
Available  
-
LVD_MAX  
Available  
2.0V Reset  
2.4V Flag  
2.4V Reset  
3.6V Flag  
3.6V Reset  
Available  
Available  
Available  
-
-
-
-
-
-
-
-
-
-
Available  
Available  
-
Available  
LVD_L  
If VDD < 2.0V, system will be reset.  
Disable LVD24 and LVD36 bit of PFLAG register.  
LVD_M  
If VDD < 2.0V, system will be reset.  
Enable LVD24 bit of PFLAG register. If VDD > 2.4V, LVD24 is “0”. If VDD 2.4V, LVD24 flag is “1”.  
Disable LVD36 bit of PFLAG register.  
LVD_H  
If VDD < 2.4V, system will be reset.  
Enable LVD24 bit of PFLAG register. If VDD > 2.4V, LVD24 is “0”. If VDD 2.4V, LVD24 flag is “1”.  
Enable LVD36 bit of PFLAG register. If VDD > 3.6V, LVD36 is “0”. If VDD 3.6V, LVD36 flag is “1”.  
LVD_MAX  
If VDD < 3.6V, system will be reset.  
Note:  
1. After any LVD reset, LVD24, LVD36 flags are cleared.  
2. The voltage level of LVD 2.4V or 3.6V is for design reference only. Dont use the LVD indicator as  
precision VDD measurement.  